Tecal RH5485 Server
Problem Determination and Service Guide
3 Diagnostics
Issue 02 (2011-05-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3-91
Message
Severity Description
Action
Sensor IOH T emp
Status has transitioned to
non-recoverable state.
Error
An internal system element has
reached an over-temperature
state.
1. Check for and correct any
system fan errors.
2. Make sure all server air
passages are clear of debris or
dust.
3. (Trained service technician
only) Replace the I/O board.
Sensor IOH T emp
Status has transitioned to
critical from a non-
recoverable state.
Error
An internal system element has
reached an over-temperature
state.
1. Check for and correct any
system fan errors.
2. Make sure all server air
passages are clear of debris or
dust.
3. (Trained service technician
only) Replace the I/O board.
Sensor IOH T emp
Status has transitioned to
non-recoverable from
a less severe state.
Error
An internal system element has
reached an over-temperature
state.
1. Check for and correct any
system fan errors.
2. Make sure all server air
passages are clear of debris or
dust.
3. (Trained service technician
only) Replace the I/O board
Sensor IOH T emp
Status has transitioned to
crititcal from a less severe
state.
Error
An internal system element has
reached an over-temperature
state.
1. Check for and correct any
system fan errors.
2. Make sure all server air
passages are clear of debris or
dust.
3. (Trained service technician
only) Replace the I/O board
Processor n is operating in
a degraded state.
Warning A microprocessor is throttled
because of power management
reasons or because it is too hot.
1. Check for and correct any
system fan errors.
2. Make sure all server air
passages are clear of debris
or dust.
3. Reseat the QPI wrap card, if
installed.
4. Reseat any installed QPI
cables.
5. (Trained service technician
only) Replace the
microprocessor board.