Tecal RH5485 Server
Problem Determination and Service Guide
3 Diagnostics
Issue 02 (2011-05-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3-101
Message
Severity Description
Action
Flash of %1 from %2
failed for user
%3.
(
%1 =
CIM_ManagedElement.
ElementName
;
%2 =
Web or
LegacyCLI
;
%3 = User ID
)
Info
An attempt to update a firmware
component from the interface and
IP address has failed.
Try to update the firmware again
The Chassis Event Log
(CEL) on system %1 is
75% full.
(
%1 =
CIM_ComputerSystem.
ElementName
)
Info
The IMM event log is 75% full.
When the log is full, older log
entries are replaced by newer
ones.
To avoid losing older log entries,
save the log as a text file and
clear the log.
The Chassis Event Log
(CEL) on system %1 is
100% full.
(
%1 =
CIM_ComputerSystem.
ElementName
)
Info
The IMM event log is full. When
the log is full, older log entries
are replaced by newer ones.
To avoid losing older log entries,
save the log as a text file and
clear the log.
%1 Platform Watchdog
Timer expired for %2.
(
%1 = OS Watchdog or
Loader Watchdog;
%2 = OS Watchdog or Loader
Watchdog;
)
Error
A Platform Watchdog Timer
Expired event has occurred.
1. Reconfigure the watchdog
timer to a higher value.
2. Make sure that the IMM
Ethernet over USB interface is
enabled.
3. Reinstall the RNDIS or
cdc_ether device driver for the
operating system.
4. Disable the watchdog.
5. Check the integrity of the
installed operating system.
IMM Test Alert Generated
by %1.
(
%1 = User ID
)
Info
A user has generated a test alert
from the IMM.
No action; information only.