3 Diagnostics
Tecal RH5485 Server
Problem Determination and Service Guide
3-34
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-05-25)
3.5.3 Embedded hypervisor problems
Table 3-4
Embedded hypervisor problems
Follow the suggested actions in the order in which they are listed in the
Action column until the problem is solved.
See Chapter 4, “Parts listing, ” to determine which components are customer
replaceable units (CRU) and which components are field replaceable units
(FRU).
If an action step is preceded by “(Trained service technician only),” that step
must be performed only by a trained service technician.
Symptom
Action
An
embedded
hypervisor
device is not
listed in the
expected
boot order, or
is not in the
list of boot
devices, or a
similar
problem has
occurred.
1. Make sure the embedded hypervisor device is selected in the boot menu (in
the Setup utility and in Select Boot Device).
2. If the embedded hypervisor is on an internal flash memory device, make
sure that the internal flash memory device is seated in the connector correctly
(see “Removing the internal flash memory” and “Replacing the internal flash
memory”).
3. See the documentation that comes with the embedded hypervisor for setup
and configuration information.
4. Make sure that other software works on the server.
3.5.4 General problems
Table 3-5
General problems
Follow the suggested actions in the order in which they are listed in the
Action column until the problem is solved.
See Chapter 4, “Parts listing, ” to determine which components are customer
replaceable units (CRU) and which components are field replaceable units
(FRU).
If an action step is preceded by “(Trained service technician only),” that step
must be performed only by a trained service technician.
Symptom
Action
An LED is
not working
or a similar
problem has
occurred.
If the part is a CRU, replace it. If the part is a FRU, the part must be replaced
by a trained service technician (see “Replaceable server components” to
determine whether the part is a CRU or a FRU).