Tecal RH5485 Server
Problem Determination and Service Guide
3 Diagnostics
Issue 02 (2011-05-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3-81
Message
Severity Description
Action
Non-redundant: Insufficient
resources for Cooling Zone
2 has asserted.
Warning Redundancy is insufficient and
might degrade or interrupt system
operation.
1. Make sure that the
connectors on fans 2 and 3 are
not damaged.
2. Make sure that fan
connectors 2 and 3 on the
microprocessor board are not
damaged.
3. Make sure that the fans are
correctly installed.
4. Reseat the fans.
5. Replace the fans.
Non-redundant: Insufficient
resources for Cooling Zone
3 has asserted.
Warning Redundancy is insufficient and
might degrade or interrupt system
operation.
1. Make sure that the
connector on fan 3 is not
damaged.
2. Make sure that fan
connector
3 on the microprocessor board is
not damaged.
3. Make sure that the fan is
correctly installed.
4. Reseat the fan.
5. Replace the fans.
The Drive n Status has
been removed from unit
chassis 1.
(
n = hard disk drive number
)
Error
A drive has been removed.
Reseat hard disk drive
n
.
(
n
= hard disk drive number)
The Drive n Status has
been dis- abled due to a
detected fault.
(
n = hard disk drive number
)
Error
A drive has been disabled
because of a fault.
1. Run the hard disk drive
diagnostic test on drive n.
2. Reseat the following
components:
a. Hard disk drive b. Cable
from the
microprocessor board to
the backplane
3. Replace the following
components one at a time, in the
order shown, restarting the server
each time:
a. Hard disk drive b. Cable
from the
microprocessor board to
the backplane
c. Hard disk drive backplane
(n = hard disk drive number)