background image

Huawei Technologies Proprietary 

 

About This Manual 

Release Notes 

This manual applies to U-SYS IAD101S/101H/102H/104H Integrated 

Access Device V300R001. 

Organization 

The  manual  introduces  functions,  data  configuration,  maintenance 

and operation of the IAD101S/101H/102H/104H.  

There are six chapters and an appendix in the manual. 

Chapter 

System 

Overview

 

profiles 

location 

of 

the 

IAD101S/101H/102H/104H  in  the  NGN,  system  structure,  and 

function features of the IAD101S/101H/102H/104H. 

Chapter  2  Device  Installation

  introduces  how  to  install  the 

IAD101S/101/102/104H and load software.  

Chapter 3 Basic Configuration

 introduces how to use the command 

lines and basic configurations of IAD101S/101/102/104H. 

Chapter 4 MGCP Configuration

 introduces how to configure data of 

the IAD101S/101/102/104H. 

 

Summary of Contents for U-SYS IAD 101H

Page 1: ...Huawei Technologies Proprietary HUAWEI U SYS IAD 101S 101H 102H 104H Integrated Access Device User Manual V300R001 ...

Page 2: ...14957 Huawei Technologies Co Ltd provides customers with comprehensive technical support and service Please feel free to contact our local office or company headquarters Huawei Technologies Co Ltd Address Administration Building Huawei Technologies Co Ltd Bantian Longgang District Shenzhen P R China Postal Code 518129 Website http www huawei com Email support huawei com ...

Page 3: ...ademarks of Huawei Technologies Co Ltd All other trademarks and trade names mentioned in this manual are the property of their respective holders Notice The information in this manual is subject to change without notice Every effort has been made in the preparation of this manual to ensure accuracy of the contents but all statements information and recommendations in this manual do not constitute ...

Page 4: ...Huawei Technologies Proprietary The IAD is used indoors only Pay attention to the following when installing and using the IAD Environment ...

Page 5: ...ents Maximum ambient temperature around the equipment must not exceed 40 For safety operation the equipment should be connected to telecommunication network only with No 26 AWG or lager telephone line Power supply The voltage of the power supply shall meet the requirement of the input voltage of the power adapter The equipment only can use the AC DC adaptor that provided with the equipment In the ...

Page 6: ... Proprietary If the IAD is not in use for a long time unplug the power adapter Placement Place the IAD on a stable table Leave over 10 cm distance around the IAD for heat dissipation Do not place heavy objects on the IAD ...

Page 7: ...s and an appendix in the manual Chapter 1 System Overview profiles location of the IAD101S 101H 102H 104H in the NGN system structure and function features of the IAD101S 101H 102H 104H Chapter 2 Device Installation introduces how to install the IAD101S 101 102 104H and load software Chapter 3 Basic Configuration introduces how to use the command lines and basic configurations of IAD101S 101 102 1...

Page 8: ...ues for some parameters specifies the system configuration and collects the terms and acronyms used in the manual Appendix B Default Values introduces the default values IAD provides Appendix C System Configuration introduces the technical specifications IAD provides Appendix D Acroynms and Abbreviations introduce the Acroynms and Abbreviations Intended Audience The manual is intended for the foll...

Page 9: ...rds or arguments in square brackets are optional x y Alternative items are grouped in braces and separated by vertical bars One is selected x y Optional alternative items are grouped in square brackets and separated by vertical bars One or none is selected x y Alternative items are grouped in braces and separated by vertical bars A minimum of one or a maximum of all can be selected x y Optional al...

Page 10: ...e continuously and quickly without moving the pointer Drag Press and hold the primary mouse button and move the pointer to a certain position IV Symbols Eye catching symbols are also used in this manual to highlight the points worthy of special attention during the operation They are defined as follows Caution Warning Danger Means reader be extremely careful during the operation Note Comment Tip K...

Page 11: ...ologies Proprietary This product has been designed to comply with the requirements on environmental protection For the proper storage use and disposal of this product national laws and regulations must be observed ...

Page 12: ... 1 2 1 Hardware Installation 2 1 2 2 Software Loading 2 3 2 2 1 Setting up Configuration Environment for Loading 2 4 2 2 2 Configuring Servers for Transmitting Files 2 8 2 2 3 Loading Files by FTP TFTP 2 12 Chapter 3 Basic Configurations 3 1 3 1 Login to the Configuration Mode 3 1 3 2 Basic Commands 3 2 3 2 1 Command Structure 3 2 3 2 2 Command Modes 3 3 3 2 3 Online Help of Command Lines 3 4 3 3 ...

Page 13: ... 10 4 2 6 Configuring the Signaling Port Number of the MGC Server 4 11 4 2 7 Configuring DNS 4 11 4 3 Configuration Examples 4 12 4 3 1 Before Configuration 4 13 4 3 2 Configuring Voice Service 4 14 4 3 3 Configuring Voice Added Value Service 4 18 4 3 4 Configuring Data Service 4 19 4 3 5 Configuring One Set Two Number 4 22 Chapter 5 Troubleshooting 5 1 5 1 Common Fault locating Means 5 1 5 1 1 Sh...

Page 14: ...hnologies Proprietary iii A 1 2 Configuring MGCP Fax Mode A 7 A 1 3 Configuring Software Parameters A 8 A 1 4 Configuring MGCP Parameters A 11 A 2 Configuring Parameters of LAN Switch A 13 Appendix B Default Values B 1 Appendix C System Configuration C 1 Appendix D Acroynms and Abbreviations D 1 ...

Page 15: ...rated Access Device Table of Contents Huawei Technologies Proprietary i Table of Contents Chapter 1 System Overview 1 1 1 1 Product Introduction 1 1 1 2 Services and Functions 1 3 1 3 System Structure 1 5 1 3 1 Front Panel 1 5 1 3 2 Rear Panel 1 8 ...

Page 16: ...s manual the IAD represents the IAD101S 101H 102H 104H 1 1 Product Introduction The IAD is an access media gateway AMG based on the technologies of voice over IP VoIP and fax over IP FoIP As an important part of the next generation network NGN it provides the following Efficient and excellent voice services in the worldwide IP network Small capacity VoIP FoIP solutions for enterprises and users in...

Page 17: ...he IAD series include four models as listed in Table 1 1 Table 1 1 External ports of the IAD Device Ports IAD101S One WAN port one LAN port and one POTS port IAD101H One WAN port one LAN port one POTS port and one PSTN emergency port IAD102H One WAN port one LAN port two POTS ports and one PSTN emergency port IAD104H One WAN port one LAN port and four POTS ports The IAD is located at user access l...

Page 18: ... the NGN SoftSwitch IAD101S 101 102 104H SG iOSS IAD101 102 104H AAA 3rd party server MRS Ephone Phone Fax PC TMG SIP mutlimedia terminal Phone Fax PC PSTN SoftSwitch TMG IP Network Figure 1 2 IAD location in the NGN 1 2 Services and Functions The IAD supports MGCP Media Gateway Control Protocol SIP Session Initiation Protocol and provides abundant voice and data services as listed below ...

Page 19: ...rting one set with two numbers and PSTN emergency the IAD101H 102H only Supporting Point to Point Protocol over Ethernet PPPoE Supporting Network Address Translation NAT II Audio Functions Supporting traditional PSTN services Supporting KC charging and polarity reversal charging controlled by the SoftSwitch IAD of MGCP only Supporting Differentiated Services Codepoint DSCP Supporting Comfort Noise...

Page 20: ...pporting Quality of Service QoS test on the bearer network Supporting usage under execrable environments Supporting end to end signaling tracing and locating software hardware faults inside devices Supporting IAD authentication by SoftSwitch Supporting encryptionf RF C2833 controlled by SoftSwitch the IAD of SIP only Supporting certifications such as Federal Communications Commission FCC Council o...

Page 21: ...Indicator Color Name Status Description On The device is being supplied with power PWR Green Power supply indicator Off No power supply On The WAN connection is established Not supported by IAD104H Blinking IAD104H only The connection is established and there are data being sent or received WAN Green Upstream port indicator Off No WAN connection LAN Green Downstrea m port indicator On The device i...

Page 22: ...nnection is established and there are data being sent or received The device is not connected to a LAN Off No data are being sent or received On The VoIP service is ready Off The device is starting or the VoIP service is unready VoIP Green VoIP service indicator Blinking 0 25s 0 25s The data is being saved PHONE1 PHONE 4 Green Phone indicator Blinking 0 25s 0 25s The phone connecting to this port ...

Page 23: ...ator Color Name Status Description Blinking 1 5s 0 5s The phone connecting to this port is switched to the PSTN and is being used On The phone connecting to this port is offhook including the locking status of the phone Off The phone connecting to this port is onhook 1 3 2 Rear Panel I IAD101H IAD101S Figure 1 3 shows external ports on the IAD101H rear panel ...

Page 24: ...ply port LAN Data user port WAN Upstream network port Figure 1 3 External ports of the IAD101H Compared with the IAD101H the IAD101S does not provide a LINE port PSTN Emergency port II IAD102H Figure 1 4 shows external ports on the IAD102H rear panel LINE PSTN emergency port PHONE1 PHONE2 PHONE ports PWR Local power supply port LAN Data user port WAN Upstream network port Figure 1 4 External ports...

Page 25: ... Er ro Estilo não definido Huawei Technologies Proprietary 1 10 III IAD104H Figure 1 5shows external ports on the IAD104H rear panel PWR Local power supply port CONSOLE Serial port WAN Upstream network port LAN Data user port PHONE1 PHONE4 PHONE ports Figure 1 5 External ports of the IAD104H ...

Reviews: