background image

4

 Configuration (Command Line Mode) 

U-SYS IAD101H/102H/104H Integrated Access Device 

Quick Start 

 

12 

Huawei Proprietary and Confidential        

Copyright © Huawei Technologies Co., Ltd. 

Issue 02 (2011-02-09) 

z

 

Run 

ipaddress static ip-address subnet-mask default-gateway

 to set a fixed IP 

address. 

z

 

Run 

ipaddress dhcp

 to obtain an IP address through DHCP. (A DHCP server is 

required.) 

z

 

Run 

pppoe username user-name password password

 to set the PPPoE user name 

and password, and then run 

ipaddress pppoe

 to obtain an IP address through 

PPPoE. (A PPPoE server is required, and the user name and password need to be 
set as the same as that on the PPPoE server.) 

You can run 

display ipaddress

 to view the IP address of the IAD. 

 

Changing the IP address may disconnect the Telnet connection. Then, you should establish 
the Telnet connection again with the new IP address. 

Step 3

 

Run the 

sip server index address ip-address domain user-domain-name

 command to 

set the SIP server and the user domain name. The IP address of the SIP server is 
191.168.10.20 and the user domain name is sichuan.chinamobile.com. 

TERMINAL(config)#

sip server 0 address 191.168.10.20 domain 

sichuan.chinamobile.com

 

If the prompt “Failure: Execution of command failed! Please undo the auto mode first” 
appears, run 

undo sip server auto

 to cancel the automatic mode of obtaining SIP 

server information, and set the IP address of the SIP server again. 

 

In IMS network, you can run the sip server auto command to make the IAD automatically 
obtain the IP address of P-CSCF (ie SIP server) through DHCP, or run the dns srv command 
to parse the IP addresses of SIP servers through SRV service on a DNS server. 

Step 4

 

Run the sip soft-parameter command to configure the SIP software parameters. 
The SIP software parameter configuration depends on the actual situation. The 
following configuration is only an example. 
Enter the advanced mode. 

TERMINAL(config)#

advanced

 

Use the user name for authentication. 

TERMINAL(advanced-config)#

sip soft-parameter auth-username name

 

Turn on the switch of the Tel URL. TelURL is a type of address in SIP protocol (ie 
+86-13612345678), which differs from SIPURL (ie wangwang@traveller.com). 

TERMINAL(advanced-config)#

sip soft-parameter support-telurl on

 

Select new service control mode as local control to support forwarding new service 
invite mode. 

TERMINAL(advanced-config)#

sip soft-parameter new-service-mode local

 

Turn on the green call service switch. 

TERMINAL(advanced-config)#

sip soft-parameter support-in-band-dtmf on

 

Return to the global configuration mode. 

 

Summary of Contents for U-SYS IAD101H

Page 1: ...U SYS IAD101H 102H 104H Integrated Access Device V300R001C03 Quick Start Issue 02 Date 2011 02 09 HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ......

Page 3: ...Co Ltd 1 Contents 1 Packing List 2 2 Safety Precautions 3 3 Installation 5 4 Configuration Command Line Mode 6 4 1 Logging In Through Telnet 6 4 2 IAD SIP Accessing NGN IP PBX 7 4 3 IAD MGCP Accessing NGN IP PBX 9 4 4 IAD SIP Accessing IMS 11 4 5 Accessing Network Through the IAD 13 4 6 Setting the UCEMS Parameters 14 5 FAQ 16 6 Technical Specifications 17 ...

Page 4: ...echnologies Co Ltd Issue 02 2011 02 09 1 Packing List After you unpack the product package check the items in the following table If the i the package are different from those in the table contac rson tems in t the sales pe Item Quantity IAD101H 102H 104H 1 Power supply adapter 1 Network cable 1 CD ROM 1 Quick Start 1 Certificate 1 ...

Page 5: ...ters and batteries The power supply voltage must meet the requirement on the input voltage of the device z Keep the power plug clean and dry to avoid the electric shock an risks Keep your hands dry when plugging in or out the device cable Stop the device and turn off the power before plugging in or out the device cable In the lightning weather turn off the power and remove all the cables from the ...

Page 6: ...ments z Keep the device dry when storing transporting and using the device z Avoid the collision when storing transporting and using the device z Place the device in the indoor environment with good ventilation and without direct and strong sunlight z Keep the device clean to avoid dust z Do not place any object on the device to avoid the overheating of the device or damage caused by extrusion z C...

Page 7: ...sed for connecting to the uplink device Use a cable to connect to the network adapter of the uplink device such as switch and route 3 Connect the power off survival port for only IAD101H 102H Use a phone line to connect to the phone port thus accessing the PSTN 2 Use a phone to connect to a phone 4 Use a cable to connect to the LAN port 5 Use the power adapter to connect to the PWR port The IAD101...

Page 8: ...et 4 2 IAD SIP Accessing NGN IP PBX 4 3 IAD MGCP Accessing N 4 4 IAD SIP Accessing IMS 4 5 Accessing Network Through the gging In Through Telnet The LAN port IP address of the IAD101H 102H 104H is 192 168 100 1 by default You can access the command line interface CLI of the IAD through Telnet For IAD104H serial port is an alternative access The CLI includes an interactive Help compl Proced re Conn...

Page 9: ...splayed Enter the user name root by default and password admin by default 4 2 IAD SIP Accessing NGN IP PBX When the network is normally connected if the IAD registers with the SIP server for example Softswitch successfully it can implement the voice call function Data Preparation Before configuring the IAD you should obtain the following items of data from the administrator Item Data Example IAD I...

Page 10: ... IP address is 191 168 10 20 TERMINAL config sip server 0 address 191 168 10 20 If the prompt Failure Execution of command failed Please undo the auto mode first appears run undo sip server auto to cancel the automatic mode of obtaining SIP server information and set the IP address of the SIP server again You can set the index to 1 or 2 to configure backup SIP servers The IAD registers to the SIP ...

Page 11: ...Prerequisite Since the IAD uses the SIP protocol mode by default you must run protocol mode mgcp to switch the IAD into the MGCP protocol mode You can run display protocol mode to view the current protocol mode Data Preparation Before configuring the IAD you should obtain the following items of data from the administrator Item Data Example IAD IP address The IP address is obtained through DHCP IP ...

Page 12: ...red domain Run mgcp mg domain name name The name of the IAD which is registered on the MGC server is iad001 TERMINAL config mgcp mg domain name iad001 Step 4 Run the mgcp mgc index address ip address command to configure the MGC server For the MGC server the index is 1 the IP address is 191 168 10 20 TERMINAL config mgcp mgc 1 address 191 168 10 20 You can set the index to 2 to configure a backup ...

Page 13: ...inamobile com SIP user ID Plan user IDs to 862821010300 and 862821010301 SIP user name Plan user names to 862821010300 sichuan chinamobile com and 862821010301 sichuan chinamobile com SIP user password Plan passwords of the two users to both 111 Procedure Step 1 Log in to the CLI with the user name root and password admin and then run the following commands to enter the global configuration mode E...

Page 14: ...om If the prompt Failure Execution of command failed Please undo the auto mode first appears run undo sip server auto to cancel the automatic mode of obtaining SIP server information and set the IP address of the SIP server again In IMS network you can run the sip server auto command to make the IAD automatically obtain the IP address of P CSCF ie SIP server through DHCP or run the dns srv command...

Page 15: ...splay sip attribute 0 Sip User Information user sn 0 id 862821010300 password name 862821010300 sichuan chinamobile com local address 192 168 1 203 local port 5060 registration state registered expire time 120 sec previous server 0 0 0 0 5060 current server 191 168 10 20 5060 dm match delay 0 ms digit map position remote After the registration is successful two registered users can talk with each ...

Page 16: ...IAD you can set the basic parameters for the communication with the Unified Communication Element Management System UCEMS so that the IAD can accept the management from the UCEMS Before setting the UCEMS parameters run the display physical serial num command to view the physical serial number If the configuration is inconsistent with that on the UCEMS To obtain the physical serial number set on th...

Page 17: ...1 normal secondary unconfig unconfiged get community public set community private trap community public trap port 162 nms access value Enable register nms ip 192 168 1 201 register state succeed handshake on handshake time 30 S register switch on If the register state field displays succeed it indicates that the IAD has registered to the UCEMS successfully For other parameters of the UCEMS it is r...

Page 18: ...ogging to the IAD run the enable and configure terminal commands to enter the global configuration mode Then run the restore vendor config command Q How is the IAD configured to support the pulse dialing function A Assume that the pulse dialing function needs to be enabled on port 0 of the IAD After logging in to the IAD run enable configure terminal and advanced to enter the advanced mode Then ru...

Page 19: ...ption IAD101H 4 9 W IAD102H 6 1 W IAD104H 7 4 W Power supply adapter 2H D104H 100 V 240 V AC 5V DC IAD101H 10 12V DC IA Working temperature 0 C 40 C Working humidity 5 95 no condensing Dimensions H 234 mm depth x 170 mm width x height IAD101H 102H 146 mm depth x 190mm width x 36 mm height IAD104 36 mm Weight 500 g Subscriber line distance the subscriber line diameter is 0 4 104H 2 0 km mm and the ...