Procedure
Step 1
Add the EMU, with the type of fan.
huawei(config)#
emu add 1 FAN 0 6 rs485 Fan
Step 2
Configure the speed adjustment mode for the fans.
huawei(config)#
interface emu 1
huawei(config-if-fan-1)#
fan speed mode automatic
Step 3
Configure the alarm reporting for the fans.
huawei(config-if-fan-1)#
fan alarmset block permit
huawei(config-if-fan-1)#
fan alarmset read-tem-fault permit
huawei(config-if-fan-1)#
fan alarmset tem-high permit
huawei(config-if-fan-1)#
fan alarmset fault permit
Step 4
Query the parameters of the fans.
huawei(config-if-fan-1)#
display fan system parameter
EMU ID: 1
FAN configration parameter:
------------------------------------------------------------------
FAN timing mode: Auto timing
------------------------------------------------------------------
Alarm_name Permit/Forbid
Read temperature fault Permit
Fan block Permit
Temperature high Permit
Power fault Permit
-------------------------------------------------------------------
Step 5
Save the data.
huawei(config-if-fan-1)#
quit
huawei(config)#
save
----End
UA5000 Universal Access Unit