lists the recommended power cable specifications for the 6 kVA and 10 kVA UPS.
Table 3-2
Recommended power cable specifications
Model
Wiring
Terminal
Rated
Voltage
External
Circuit
Breaker
Cross-sectional
Area
Terminal
Type
Torque for
Tightening
Bolts
6 kVA
Input
220 V AC,
230 V AC,
or 240 V
AC
50 A (feature
D)
6 mm
2
OT-10 mm
2
-
M6 terminal
2.8 N·m
Output
50 A (feature
D)
Battery
240 V DC
50 A
6 mm
2
10 kVA
Input
220 V AC,
230 V AC,
or 240 V
AC
63 A (feature
D)
10 mm
2
OT-10 mm
2
-
M6 terminal
2.8 N·m
Output
63 A (feature
D)
Battery
240 V DC
63 A
10 mm
2
If customers purchase input and output power cables by themselves, use the cables that comply with
standards proposed by Underwriters Laboratories (UL) or International Electrotechnical Commission
(IEC).