Item
Specification
Redundant power supply
Two power modules are supported for
1+1 power redundancy.
Long-term operating temperature
[°C(°F)]
0°C to 45°C
Storage temperature [°C(°F)]
-40°C to 70°C
Long-term operating relative humidity
[RH]
5% RH to 95% RH, non-condensing
Storage relative humidity [RH]
5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)]
0 m to 5000 m
Storage altitude [m(ft.)]
0 m to 5000 m
NO TE
● The width does not include the size of mounting ears.
● The height is 1U (1U = 1.75 inches, or about 44.45 mm), which is a height unit defined
in International Electrotechnical Commission (IEC) 60297 standards.
● Temperature and humidity are measured 1.5 m above the floor and 0.4 m in front of the
rack when no protection plate exists before or after the rack.
4.1.10 USG6575E-B
Overview
Table 4-55 Basic information about the USG6575E-B
Description
Part Number
Model
First
Supported
Version
Remarks
USG6575E-B
AC Host
(16*GE
RJ45+8*GE
Combo
+2*10GE SFP
+,1 AC Power)
02353LKD
USG6575E-B-
AC
V600R007C20 -
HUAWEI USG6000E Series
Hardware Guide
4 Hardware Overview
Issue 08 (2022-04-20)
Copyright © Huawei Technologies Co., Ltd.
130