5.3 Installing a Desktop Device
This chapter provides the cabinet-mounting, workbench-mounting, wall-mounting,
and cable connection methods of the USG6510E, USG6510E-POE, USG6530E.
5.3.1 Mounting a Device to a Specified Location
The USG6510E, USG6510E-POE, USG6530E can be mounted in a 19-inch standard
cabinet. When no cabinet is available, install the USG6510E, USG6510E-POE,
USG6530E on a workbench or a wall.
5.3.1.1 Mounting a Device in a Cabinet
The USG6510E, USG6510E-POE, USG6530E can be mounted in a 19-inch standard
cabinet using mounting ears.
Precautions
Before installing the USG, check the following items:
●
Before unpacking the carton, ensure that the packing carton is intact and not
damaged or soaked. Stop unpacking if the USG is rusted or soggy. Then,
investigate causes and contact the supplier.
●
The cabinet is stable.
●
The position for the USG in the cabinet is well arranged.
●
Ensure that the USG is 1 U of clearance from any devices above and below
and 150 mm of clearance from any devices on the right or left.
●
The device to be installed is staged near the cabinet for convenience.
You can place either end of the USG chassis towards the front door of the cabinet.
In this manual, the front panel of the USG is towards the front door of the
cabinet.
Tools and Accessories
●
Phillips screwdriver
●
Floating nuts and matching screws
●
Floating mounting bar
●
Mounting ears and matching screw (purchased separately, BOM numbers:
21240477)
●
Holding plate and matching screw (purchased separately, BOM numbers:
21243646)
Procedure
Step 1 Install mounting ears on the chassis.
Use a Phillips screwdriver to fix the mounting ears to both sides of the chassis
with M4 screws, as shown in
.
HUAWEI USG6000E Series
Hardware Guide
5 Hardware Installation
Issue 08 (2022-04-20)
Copyright © Huawei Technologies Co., Ltd.
512