Name
Description
Console interface
It connects to the console for on-site configuration of the
system.
AUX interface
It connects to the Modem for remote maintenance through
dialing.
Others
CLK
They are reserved to input or output clock signals.
TOD
Interface Attributes
lists the attributes of the 10Base-T/100Base-TX/1000Base-T-RJ45 interfaces.
Table 1-48
10Base-T/100Base-TX/1000Base-T-RJ45 interface attributes
Attribute
Description
Connector type
RJ45
Operation mode
10M/100M/1000M auto-sensing interfaces, supporting full-
duplex mode
Standards compliance
IEEE 802.3-2002
Cable specification
Category 5 unshielded twisted pair (UTP) cables recommended
when the interface rate is 10 Mbit/s or 100 Mbit/s; super
category 5 Shielded Twisted Pair (STP) cables recommended
when the interface rate is 1000 Mbit/s
lists the console interface attributes.
Table 1-49
Console interface attributes
Attribute
Description
Connector type
RJ45
Operation mode
Duplex Universal Asynchronous Receiver/Transmitter (UART)
Electrical attribute
RS-232
Baud rate
9600 bit/s (default value), which can be changed as required
Data equipment type
Data Circuit-terminating Equipment (DCE)
Cable specification
8-core shielded cable
HUAWEI USG9500 Series
Hardware Guide
1 Hardware Overview
Issue 03 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
106