Distance from the PDF to
the Device
Power Cables a and b
Wire,450/750V,227 IEC
02(RV)16mm
2
,black,85A
Each power module should
be equipped with one cable
of this type. The cable
length is determined by an
on site project survey.
Naked Crimping
Terminal,JG2,16mm
2
,M6,95
A,Tin Plated,for OEM
Each cable should be
equipped with one terminal
of this type.
Naked Crimping
Terminal,OT,16mm
2
,M8,Tin
Plating,Naked Ring
Terminal
Each cable should be
equipped with one terminal
of this type.
Longer than 15 m or shorter
than or equal to 25 m
Wire,450/750V,227 IEC
02(RV)25mm
2
,blue,110A
Each power module should
be equipped with one cable
of this type. The cable
length is determined by an
onsite project survey.
Wire,450/750V,227 IEC
02(RV)25mm
2
,black,110A
Each power module should
be equipped with one cable
of this type. The cable
length is determined by an
onsite project survey.
Naked Crimping
Connector,JG2,25mm
2
,M6,1
50A,Tin Plating,For OEM
Each cable should be
equipped with one terminal
of this type.
Naked Crimping
Terminal,OT,25mm
2
,M8,Tin
Plating,Naked Ring
Terminal
Each cable should be
equipped with one terminal
of this type.
Longer than 25 m or shorter
than or equal to 35 m
Wire,450/750V,227 IEC
02(RV)35mm
2
,Blue,135A
Each power module should
be equipped with one cable
of this type. The cable
length is determined by an
onsite project survey.
Wire,450/750V,227 IEC
02(RV)35mm
2
,black,135A
Each power module should
be equipped with one cable
of this type. The cable
length is determined by an
onsite project survey.
HUAWEI USG9500 Series
Hardware Guide
2 Hardware Installation
Issue 03 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
324