1.4.5.7 3-Port 40GBase QSFP+ FPIC (FW-3X40G-QSFP+)
The FW-3X40G-QSFP+ occupies one 1/2-width flexible card slot, is compatible with
LPUF-240s and LPUF-120s, works in LAN mode, uses QSFP+ optical modules, but is not
hot-swappable.
Panel
shows the FW-3X40G-QSFP+.
Figure 1-80
FW-3X40G-QSFP+
ST
ATUS
FW-3X40G-QSFP+
RX
TX
L/A
RX
TX
L/A
RX
TX
L/A
Name
Description
STATUS (green)
l
Blinks every 2 seconds (0.5 Hz): The system is working
properly.
l
Blinks twice each second (2 Hz): The system is in the alarm
state.
L/A (green)
l
Steady on: The link is connected.
l
Blinking: Data is being transmitted or received.
l
Off: The link is disconnected.
Interface Attributes
lists the attributes of interfaces on FW-3X40G-QSFP+.
Table 1-87
FW-3X40G-QSFP+ interface attributes
Attribute
Description
Connector type
LC/PC
Optical interface
attributes
Compliant with the selected SFP+ optical module. For details about the
optional attributes of the optical module, see
.
Working mode
Full-duplex
Standards
compliance
IEEE 802.3-2002
Frame format
Ethernet_II, Ethernet_SAP, and Ethernet_SNAP
HUAWEI USG9500 Series
Hardware Guide
1 Hardware Overview
Issue 03 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
151