Step 6
Install the chassis cover.
Step 7
Turn on the power to the server and observe the mount process.
l
If the ES3000 is successfully mounted, the problem is resolved.
l
If the fault persists, contact Huawei Technical Support.
----End
Reference Information
None
5.1.3 Querying and Setting the Fan Speed (fanlevel)
This topic describes how to use the
fanlevel
command to query and set the fan speed.
Function
The
fanlevel
command is used to query and set the fan speed.
Format
ipmcget -d fanlevel
ipmcset -d fanlevel -v percent
Parameters
Parameter Description
Value
percent
Indicates the percentage of the current fan
speed to the full fan speed.
The value is an integer ranging from
38-100.
Usage Guidelines
The
percent
parameter is available only in manual mode.
Then the MMC sets the fan speed to the highest value sent from the iManas of all node servers.
Example
# Run the following command to query the fan speed:
The following information is displayed when the fans are operating in automatic mode:
root@BMC:/#
ipmcget -d fanlevel
Get fanlevel successfully!
Current mode: auto.
The following information is displayed when the fans are operating in manual mode:
root@BMC:/#
ipmcget -d fanlevel
Get fanlevel successfully!
Current mode:manual,timeout 489 seconds.
Manual fan level: 50%