2.4.2 Monitoring Device Does Not Receive Any Mirrored Packets
After Traffic Mirroring Is Configured
This section describes the troubleshooting flowchart and provides a step-by-step troubleshooting
procedure for the failure to monitor packets to the monitoring device by traffic mirroring.
Common Causes
This fault is commonly caused by one of the following:
l
The link between the mirrored port and the monitored network is Down.
l
No traffic policy is applied or no packets match the traffic policy.
l
The observing port index specified in the traffic behavior is different from the index of the
configured observing port.
Troubleshooting Flowchart
After traffic mirroring is configured on the AR2200-S, the monitoring device does not receive
any mirrored packets.
shows the troubleshooting flowchart.
Huawei AR2200-S Series Enterprise Routers
Troubleshooting
2 System
Issue 01 (2012-01-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
20