Figure 5-32
Indicators on a disk module
1
Running indicator of
the disk module
2
Alarm/Location
indicator of the disk
module
Step 8
Confirm the replacement.
1.
Perform a post-replacement inspection.
After the parts replacement, return to the SmartKit page and click
Replaced
. Then
complete the check after the replacement as prompted.
2.
Check system status.
On the
Parts Replacement
page, click
Inspection
to check the system status again. If
any inspection item fails, rectify the fault based on the suggestions in the inspection
report.
3.
After the preceding procedure is complete, check services on the host for any storage-
related error.
----End
Follow-up Procedure
After the disk module is replaced, label it to facilitate subsequent operations.
5.5 Replacing a Controller
This section describes how to replace a controller.
5.5.1 Replacing a Controller (for Dorado5000 V3)
This section describes how to replace a controller.
OceanStor Dorado V3 Series
Parts Replacement
5 Replacing FRUs
Issue 05 (2019-01-30)
Copyright © Huawei Technologies Co., Ltd.
104