l
If no, cable connections are incorrect, components are incorrectly installed, or the data
switch is faulty.
Step 8
Confirm the replacement.
1.
Perform a post-replacement inspection.
After the parts replacement, return to the SmartKit page and click
Replaced
. Then
complete the check after the replacement as prompted.
2.
Check system status.
On the
Parts Replacement
page, click
Inspection
to check the system status again. If
any inspection item fails, rectify the fault based on the suggestions in the inspection
report.
3.
After the preceding procedure is complete, check services on the host for any storage-
related error.
----End
Follow-up Procedure
After the replacement is complete, label the replaced data switch to facilitate subsequent
operations.
5.14 Replacing the Parts of a Quorum Server
This chapter describes how to replace the parts of a quorum server.
lists the parts that can be replaced for a quorum server.
Table 5-2
Parts that can be replaced for a quorum server
Part
Active-Active Service Affected or Not
Entire quorum server
If you power off the quorum server, the
arbitration mode of the active-active service
services changes to the static priority mode.
The reliability of the active-active services
decreases.
Disk module
Power module
NOTE
l
For details about how to replace the parts of a quorum server, such as the VGA board, indicator
board, and disk backplane, see the
Huawei Rack Server Product Documentation
.
l
1288H V5 and RH1288 V3 servers can be used as quorum servers. 1288H V5 is used as an example
in the following operations.
5.14.1 Replacing an AC Power Module
This section describes how to replace an AC power module.
OceanStor Dorado V3 Series
Parts Replacement
5 Replacing FRUs
Issue 05 (2019-01-30)
Copyright © Huawei Technologies Co., Ltd.
192