0 192.168.6.31 30002 192.168.6.17
44510 Established
1 192.168.6.31 30002 192.168.6.18
36836 Established
2 192.168.7.31 30002 192.168.7.16
57416 Established
3 192.168.7.31 30002 192.168.7.28
49752 Established
–
If yes, the quorum server can work properly.
–
If no, check whether the IP addresses of the quorum server are correct.
5.14.3 Replacing a Quorum Server
This section describes how to replace a quorum server.
Impact on the System
The services and programs running on a quorum server will be interrupted when it is
removed. The arbitration mode of the active-active services automatically switches to the
static priority mode.
Prerequisites
l
The spare part and its components are ready.
l
The quorum server to be replaced has been located.
l
All services and programs on the quorum server have been stopped, and the quorum
server has been powered off.
l
Data has been backed up for the quorum server before it is removed.
l
The cable connection positions on the quorum server to be replaced have been clearly
marked.
Precautions
l
Remove or insert a quorum server with even force. Excessive force may damage the
appearance or connectors of the quorum server.
l
The quorum server is heavy so that at least two persons are required to move it.
Tools and Materials
l
ESD wrist strap or ESD gloves
l
Screwdriver
Procedure
Step 1
Power off the quorum server.
Step 2
Remove the quorum server.
1.
Disconnect all power cables and signal cables from the quorum server.
2.
Loosen the captive screws on the quorum server panel using a screwdriver. See step (1)
in
OceanStor Dorado V3 Series
Parts Replacement
5 Replacing FRUs
Issue 05 (2019-01-30)
Copyright © Huawei Technologies Co., Ltd.