Step 10
Confirm the replacement.
After the preceding procedure is complete, check services on the host for any storage-related
error. If any storage-related error is reported, contact Huawei technical support.
----End
Follow-up Procedure
After the power module is replaced, label it to facilitate subsequent operations.
4.1.3 Replacing a Power Module (for Dorado18000 V3)
This section describes how to replace a power module.
Impact on the System
During the replacement of a power module, if the redundant power module fails, the
corresponding controller is powered by a BBU and the system reliability degrades.
Prerequisites
l
The spare part is ready.
l
The power module that you want to replace has been located.
NOTE
You can locate a component in either of the following ways:
l
Locating a component based on alarms in DeviceManager: On the
Alarms and Events
page
of DeviceManager, view the help information and locate the component to be replaced.
l
Locating a component based on the status of its Running/Alarm indicator: For details about the
indicators on different components, see
4.4 Running/Alarm Indicators on Power Modules,
.
l
The other power module works properly.
Precautions
l
Do not touch the connectors of a power module and a power cable.
l
Remove and insert a power module with even force. Excessive force may damage the
appearance or connectors of the power module.
l
Remove only one power module at a time.
l
A power module must be replaced within five minutes. Otherwise, the system heat
dissipation is compromised.
Tools and Materials
l
ESD wrist strap
l
ESD bag
l
Labels
OceanStor Dorado V3 Series
Parts Replacement
4 Replacing CRUs
Issue 05 (2019-01-30)
Copyright © Huawei Technologies Co., Ltd.
24