Procedure
Step 1
Perform a pre-replacement check.
Check whether there is a redundant power module and whether the Running/Alarm indicator
of the redundant power module is steady green, as shown in
. For details about
the indicators on different components, see
Running/Alarm Indicators on a Dorado18000
.
Figure 4-19
Running/Alarm indicator on a power module
You can perform replacement only when a redundant power module exists and the redundant
power module is working properly.
Step 2
Wear an ESD wrist strap.
Step 3
Remove the power cable.
1.
Loosen the retention clip, as shown in step 1 in
.
Figure 4-20
Removing the AC power cable
2.
Pull up the retention clip, as shown in a of step 2 in
3.
Remove the AC power cable, as shown in b of step 2 in
Step 4
Press the latch on the inner side of the power module handle and pull out the power module,
as shown in
.
OceanStor Dorado V3 Series