Figure 4-10
Running/Alarm indicator on a power module
Step 12
Confirm the replacement.
After the preceding procedure is complete, check services on the host for any storage-related
error. If any storage-related error is reported, contact Huawei technical support.
----End
Follow-up Procedure
After the power module is replaced, label it to facilitate subsequent operations.
4.1.2 Replacing a Power Module (for Dorado6000 V3)
This section describes how to replace a power module. Except that there is a slight difference
on removing and inserting power cables between AC and DC power modules, other
operations performed for them are the same. This section uses AC power modules as an
example.
Impact on the System
During the replacement of a power module, if the redundant power module fails, the
corresponding controller is powered by a BBU and the system reliability degrades.
Prerequisites
l
The spare part is ready.
l
The power module that you want to replace has been located.
NOTE
You can locate a component in either of the following ways:
l
Locating a component based on alarms in DeviceManager: On the
Alarms and Events
page
of DeviceManager, view the help information and locate the component to be replaced.
l
Locating a component based on the status of its Running/Alarm indicator: For details about the
indicators on different components, see
4.4 Running/Alarm Indicators on Power Modules,
.
l
The other power module works properly.
OceanStor Dorado V3 Series
Parts Replacement
4 Replacing CRUs
Issue 05 (2019-01-30)
Copyright © Huawei Technologies Co., Ltd.
18