NOTE
You can locate a component in either of the following ways:
l
Locating a component based on alarms in DeviceManager: On the
Alarms and Events
page
of DeviceManager, view the help information and locate the component to be replaced.
l
Locating a component based on the status of its Running/Alarm indicator: For details about the
indicators on different components, see
4.4 Running/Alarm Indicators on Power Modules,
.
Precautions
l
Do not touch the connectors of a power module and a power cable.
l
Remove and insert a power module with even force. Excessive force may damage the
appearance or connectors of the power module.
l
Remove only one power module at a time.
l
A power module must be replaced within three minutes. Otherwise, the system heat
dissipation is compromised.
Tools and Materials
l
ESD wrist strap
l
ESD bag
l
Label
l
Phillips screwdriver
Procedure
Step 1
Perform a pre-replacement check.
Check whether there is a redundant power module and whether the Running/Alarm indicator
of the redundant power module is steady green, as shown in
. For details about
the indicators on different components, see
Running/Alarm Indicators on a 2 U Disk
Figure 4-25
Running/Alarm indicator on a power module
You can perform replacement only when a redundant power module exists and the redundant
power module is working properly.
OceanStor Dorado V3 Series
Parts Replacement
4 Replacing CRUs
Issue 05 (2019-01-30)