Table 4-1
Indicators on the rear panel of a controller enclosure
No.
Indicator
Status and Description
1
Running/Alarm
indicator on a
BBU
l
Steady green: The BBU is fully charged.
l
Blinking green (1 Hz): The BBU is being charged.
l
Blinking green (4 Hz): The BBU is being discharged.
l
Steady red: The BBU is faulty.
2
Running/Alarm
indicator on a
power module
l
Steady green: The power module is working properly.
l
Blinking green: The power input is normal but the device
is powered off.
l
Steady red: The power module is faulty.
l
Off: No external power is input.
Running/Alarm Indicators on a Dorado6000 V3 Controller Enclosure
shows the indicators on the front panel of a controller enclosure.
Figure 4-66
Indicators on the front panel of a controller enclosure
1
Running/Alarm indicator on a
BBU
2
Running/Alarm indicator on a fan
module
describes the indicators on the front panel of a controller enclosure.
Table 4-2
Indicators on the front panel of a controller enclosure
No.
Indicator
Status and Description
1
Running/Alarm
indicator on a
BBU
l
Steady green: The BBU is fully charged.
l
Blinking green (1 Hz): The BBU is being charged.
l
Blinking green (4 Hz): The BBU is being discharged.
l
Steady red: The BBU is faulty.
OceanStor Dorado V3 Series
Parts Replacement
4 Replacing CRUs
Issue 05 (2019-01-30)