ViewPoint 8650
Quick Start Guide
3 First Use
Issue 04 (2013-07-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
11
Power and ground cable labels (including power switch labels) are correctly filled in and
consistently attached. If possible, attach the labels 20 mm (0.79 in.) away from the cable
connectors.
The power and ground cables are 30 mm (1.18 in.) away from the signal cable outside
the cabinet.
Verifying Power Supply
Ensure that the performance of the external AC power supply meets the requirements.
3.2 Powering On the MCU
Context
Do not install both AC and DC power modules in the MCU.
Procedure
Step 1
Use the power cable to connect the AC power module of the MCU to the power socket on the
wall.
Step 2
Switch on the power switch of the MCU.
Figure 3-1
AC power supply