8
6. List of Manufacturer Parameters
Ⅵ
. List of Manufacturer Parameters
Parameters used to store relevant data set by air compressor manufacturers. To view manufacturer
parameters, the manufacturer password must be verified. In the first-level menu, press
or
key to
move the black scroll bar to the "Manufacturer Parameters" menu, and then press
key to enter the
menu below:
After entering the correct manufacturer password
and pressing key, user can enter the manufacturer
parameter interface as shown below:
Parameter Item
Initial Value
Function
System
Parameters
Air End 1
Current
Maximum
allowable
motor
overload
current / 1.2
After delay start of Air End 1, the machine will
present a delay shutdown according to overload
characteristics when the motor current is more
than 1.2 times of the set value.
Air End 2
Current
Maximum
allowable
motor
overload
current / 1.2
After delay start of Air End 2, the machine will
present a delay shutdown according to overload
characteristics when the motor current is more
than 1.2 times of the set value.
Temperature
1
Warning
105
℃
When Air End 1 temperature is higher than this
set temperature, a warning will be given.
Temperature
1
Shutdown
110
℃
When Air End 1 temperature is higher than this
set temperature, fault shutdown will be reported.
Shutdown
Pressure
1.00MPa
When the air supply pressure is higher than the
set pressure, fault shutdown will be reported.
Maximum
Unload
Pressure
0.80MPa
Maximum allowable unloading pressure limited
by manufacture on user settings. Unloading
pressure is less than or equal to this set value.
Air End 1
Time
000000 hrs
Modify the total running time of Air End 1.
System Parameters
Maintenance Parameter Reset
Maximum Operating Time Preset
Enter Password
****