background image

Manual M-800 Rev. 6/09

Manual M-800 Rev. 6/09

SERVICE AND OPERATION MANUAL

PW115/230V-HD HYDRAULIC POWER PUMP

ELECTRIC

TWO-STAGE HYDRAULIC PUMP

NOTE: Read and carefully follow these instructions. Most problems with 
new equipment are caused by improper operation or installation.

To help avoid personal injury:
Hydraulic Hose

•  Before operating the pump, all hose connections must be tightened 

with the proper tools. Do not overtighten. Connections should only be 
tightened securely and leak-free. Overtightening can cause premature 
thread failure or high pressure fittings to split at pressures lower than 
their rated capacities.

•  Should a hydraulic hose ever rupture, burst, or need to be disconnected, 

immediately shut off the pump and shift the control valve twice to release 
all pressure. Never attempt to grasp a leaking hose under pressure with 
your hands. The force of escaping hydraulic fluid could cause serious 
injury.

•  Do not subject the hose to potential hazard such as fire, sharp surfaces, 

extreme heat or cold, or heavy impact. Do not allow the hose to kink, 
twist, curl, or bend so tightly that the oil flow within the hose is blocked 
or reduced. Periodically inspect the hose for wear, because any of these 
conditions can damage the hose and result in personal injury.

•  Do not use the hose to move attached equipment. Stress can damage 

the hose and cause personal injury.

•  Hose material and coupler seals must be compatible with the hydraulic 

fluid used. Hoses also must not come in contact with corrosive materials 
such as creosote-impregnated objects and some paints. Consult the 
manufacturer before painting a hose. Never paint the couplers. Hose 
deterioration due to corrosive materials can result in personal injury.

WARNING

!           

Page 1 of 16

Page 16 of 16

HMIS (US):  

Health Hazard 

1

 

Fire Hazard 

1

 

Reactivity 

0

 

Personal Protection 

8

NFPA (USA): 

Health Hazard 

1

 

Fire Hazard 

1

 

Reactivity 

0

 

Specific Hazard 

none

Rating 

Insignificant

 

Slight

 

Moderate

 

High

 

Extreme

Section 16. Other Informations

 

Prepared by: 

SPX Fluid Power

 

5885 11th Street

 

Rockford, IL 61109, USA

 

Phone: 815-874-5556

 

Fax: 815-874-7886

Date of preparation: November, 2007

The information presented herein has been 
compiled from source considered to be depend-
able and accurate to the best of SPX Fluid Power 
knowledge; however, SPX Fluid Power makes 
no warranty whatsoever, expressed or implied, 
of Merchantability or Fitness for the Particular 
Purpose, regarding the accuracy of such data or 
the results to be obtained from the user thereof. 
SPX Fluid Power assumes no responsibility for the 
injury to recipient or to the third persons or for any 
damage to any property and recipient assumes all 
such risks.

Rev. 2

Material Safety Data Sheet

Material Safety Data Sheet 

Page 3

AW Hydraulic Oil ISO 46

SAFETY PRECAUTIONS

HUBBELL

®

Power Systems

Summary of Contents for Anderson PW115V-HD

Page 1: ...ttached equipment Stress can damage the hose and cause personal injury Hose material and coupler seals must be compatible with the hydraulic fluid used Hoses also must not come in contact with corrosi...

Page 2: ...Viscosity 41 4 50 6 cSt 40 deg C Flash Point 200 deg C 392 deg F Vapor pressure Negligible at ambient temperature and pressure Specific Gravity 0 875 kg L 20 deg C 68 deg F Water solubility Insoluble...

Page 3: ...n Seek medical attention Skin Contact Remove contaminated clothing launder before reuse Wash contaminated skin with running water and non abrasive soap Get medical attention if irritation develops or...

Page 4: ...n to gradually increase the pressure setting When the desired pressure setting is reached lock the adjusting screw into position by tightening the locknut Page 4 of 16 OPERATING INSTRUCTIONS Hydraulic...

Page 5: ...pensate by releasing the pressure developed by the hydraulic pump as it coasts to a stop As a result the pressure limit requirement can be held to approximately 300 PSI Adjusting the Pressure Switch S...

Page 6: ...the seat area Clean and reseat if necessary Inspect for damage and replace parts if neces sary then reassemble 6 Replace after checking pump cavity for broken pieces 7 Check automatic valve seat Addin...

Page 7: ...aulic oil is of a higher viscosity than necessary 7 Relief valve or low pressure unloading valve out of adjustment 8 Reservoir capacity is too small for the size of the ram s used 9 Defective directio...

Page 8: ...amperage draw too high for existing circuit 8 Overheated motor 9 Faulty thermal protector 10 Defective motor 1 Plug in unit 2 Check line voltage Check reset button on power panel 3 Replace defective p...