TempSense Models TS200/TS200W 

Page 5 of 9 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-566A.docx 

03/21 

Configuration

 

The TempSense TS200 and TS200W have a built in webserver for configuration and calibration of the 
TempSense device. 

TempSense TS200

 

Configure the TempSense TS200 before calibrating it or using it to scan subjects: 

1.

 

Plug a Category 5e or better Ethernet cable with RJ45 plug from a PoE switch port into the TS200’s 
Ethernet jack pigtail. 

The TempSense TS200 boots up with a static, class 

C

 IP address, set to 192.168.1.55. 

2.

 

Wait several minutes for the unit to boot and come up to normal operating temperature. 

3.

 

Configure a PC to access the TempSense device on the class 

C

 network 192.168.1.

x.

 

4.

 

Open a web browser and enter 192.168.1.55 in the address bar. 

The TempSense management webpage contains sections of parameters for defaults (see Table 1)
network (see Table 2), SMTP (see Table 3) , and time (see Table 4)

5.

 

Configure all settings and click 

A

PPLY CHANGES AND 

R

ESTART

The unit reboots with the configured settings. 

N

OTE

:

  If the network mode is DHCP but no DHCP server exists, the unit falls back to IP address 

192.168.1.55. 

TempSense TS200W

 

Configure the TempSense TS200W before calibrating it or using it to scan subjects as follows: 

1.

 

Plug the included power supply into the TS200W’s power cord pigtail. 

2.

 

Plug the power supply into a 120 V ac outlet. 

3.

 

Wait several minutes for unit to boot and come up to normal 
operating temperature. 

The TS200W boots up and creates a wireless network with 
following properties: 

 

WiFi frequency:  2.4 GHz 

 

SSID:  ThermalScanner 

 

IP address:  192.168.4.1 

 

subnet mask:  255.255.255.0 

 

password:  GAItronics 

4.

 

Use a PC to access the ThermalScanner WiFi access point. 

Password:  

GAItronics

 

5.

 

Open a web browser and enter 192.168.4.1 in the address bar to 
access and authenticate to the TS200W’s management webpage. 

The TempSense management webpage contains sections of 
parameters for defaults (see Table 1), network (see Table 2)
SMTP (see Table 3) , and time (see Table 4) 

 

Figure 10.  Model TS200W 

Factory Reset 

Summary of Contents for GAI-TRONICS TempSense TS200

Page 1: ...WWW GAI TRONICS COM FOR PRODUCT LITERATURE AND MANUALS Confidentiality Notice 1 General Information 1 Installation 2 Camera Location 2 Wall Mount 3 Pole Mount 3 VESA Mount 3 Stand Mount 4 Connection...

Page 2: ...eration of your GAI Tronics product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party General Information The TempSense Models TS200...

Page 3: ...closer to the camera Camera Location Locate the TempSense TS200 TS200W so that people in a queue individually pass through the two cameras shared FOV while facing the cameras Each subject scanned shou...

Page 4: ...mounting plate using the four included 6 32 screws PoleMount Mount the TempSense TS200 TS200W to a pole see Figure 5 as follows 1 Secure the TS200 see Figure 6 or TS200W see Figure 7 mounting plate t...

Page 5: ...If the IR sensor LED does not flash press the sensor into its socket using a soft cloth then reboot the device The Model TS200 boots up and is ready for configuration see the Configuration section or...

Page 6: ...and time see Table 4 5 Configure all settings and click APPLY CHANGES AND RESTART The unit reboots with the configured settings NOTE If the network mode is DHCP but no DHCP server exists the unit fal...

Page 7: ...rts after the measured temperature drops below the threshold temperature 0 100 5 seconds Offset The value to add to or subtract from the temperature measured by the TempSense 10 to 10 F 0 F 6 to 6 C 0...

Page 8: ...Pv4 address or FQDN string 0 0 0 0 time_zone The offset from UTC Select the offset from UTC using the roll box control Calibration 1 Place an object of known temperature in the field of view of the TS...

Page 9: ...rcent Allow the TS200 TS200W to operate in the testing environment for 10 30 minutes to adjust to its environment before scanning personnel Subject Preparation To obtain accurate skin temperatures ens...

Page 10: ...andard IOMs Current Release 42004 Instr Manuals 42004 566A docx 03 21 Specifications Electrical Power TS200 PoE TS200W 120 V ac Mechanical Dimensions 7 26 H 5 76 W 1 5 D in 184 4 146 3 38 1 mm Weight...

Reviews: