Table 3. SMTP Parameters
Parameter
Description
Value:
username
The username for the SMTP server mailbox
(string)
None
server
the SMTP server’s IP Version 4 address
valid IPv4 address or FQDN
(Fully Qualified Domain Name)
0.0.0.0
security
SMTP security protocol in use
TLS, SSL,
None
password
the SMTP password for the mail account
(string)
recipient
The receiver’s email address this TempSense device
sends email to.
valid SMTP email address
None
port
The I/O memory address of the SMTP service on the
host computer
0–65535,
587
Table 4. NTP Parameters
Parameter
Description
Value:
time_server
IP version 4 address for an NTP server
valid IPv4 address or FQDN
(string)
0.0.0.0
time_zone
The offset from UTC
Select the offset from UTC using
the roll box control.
Calibration
1.
Place an object of known temperature in the field of view of the TS200/TS200W at the appropriate
height and distance (see the Camera Location section).
2.
Login to the webserver and press the
C
ALIBRATE
T
HRESHOLD
AND
O
FFSET
button.
3.
While watching the temperature of the object in the IR video feed (left side), slide the
O
FFSET
slider
to adjust the on-screen temperature until it displays the known temperature (see Figure 11).
4.
Adjust the
T
EMP
T
HRESHOLD
to the desired temperature for the TS200/TS200W to send an email to
the
recipient
to alert them when a subject exceeds this temperature.
The TS200/TS200W captures both an IR and normal picture when the temperature exceeds the
T
EMP
T
HRESHOLD
value. It then waits the
automatic_scan_timeout
period after the temperature drops
below the
threshold
temperature before scanning resumes.