background image

Pub. 42004-566A 

TempSense Models TS200/TS200W 

Page 7 of 9 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-566A.docx 

03/21 

Table 3.  SMTP Parameters 

Parameter 

Description 

Value: 

username 

The username for the SMTP server mailbox 

(string) 

None

 

server 

the SMTP server’s IP Version 4 address 

valid IPv4 address or FQDN 
(Fully Qualified Domain Name) 

0.0.0.0

 

security 

SMTP security protocol in use 

TLS, SSL, 

None

 

password 

the SMTP password for the mail account 

(string) 

recipient 

The receiver’s email address this TempSense device 
sends email to. 

valid SMTP email address 

None 

port 

The I/O memory address of the SMTP service on the 
host computer 

0–65535, 

587 

 

Table 4.  NTP Parameters 

Parameter 

Description 

Value: 

time_server 

IP version 4 address for an NTP server 

valid IPv4 address or FQDN 
(string) 

0.0.0.0 

time_zone 

The offset from UTC 

Select the offset from UTC using 
the roll box control. 

 

Calibration

 

1.

 

Place an object of known temperature in the field of view of the TS200/TS200W at the appropriate 
height and distance (see the Camera Location section). 

2.

 

Login to the webserver and press the 

C

ALIBRATE 

T

HRESHOLD

 

AND

 

O

FFSET

 button. 

3.

 

While watching the temperature of the object in the IR video feed (left side), slide the 

O

FFSET

 slider 

to adjust the on-screen temperature until it displays the known temperature (see Figure 11)

4.

 

Adjust the 

T

EMP 

T

HRESHOLD

 to the desired temperature for the TS200/TS200W to send an email to 

the 

recipient

 to alert them when a subject exceeds this temperature. 

The TS200/TS200W captures both an IR and normal picture when the temperature exceeds the 

T

EMP 

T

HRESHOLD

 value.  It then waits the 

automatic_scan_timeout 

period after the temperature drops 

below the 

threshold

 temperature before scanning resumes. 

Summary of Contents for GAI-TRONICS TempSense TS200

Page 1: ...WWW GAI TRONICS COM FOR PRODUCT LITERATURE AND MANUALS Confidentiality Notice 1 General Information 1 Installation 2 Camera Location 2 Wall Mount 3 Pole Mount 3 VESA Mount 3 Stand Mount 4 Connection...

Page 2: ...eration of your GAI Tronics product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party General Information The TempSense Models TS200...

Page 3: ...closer to the camera Camera Location Locate the TempSense TS200 TS200W so that people in a queue individually pass through the two cameras shared FOV while facing the cameras Each subject scanned shou...

Page 4: ...mounting plate using the four included 6 32 screws PoleMount Mount the TempSense TS200 TS200W to a pole see Figure 5 as follows 1 Secure the TS200 see Figure 6 or TS200W see Figure 7 mounting plate t...

Page 5: ...If the IR sensor LED does not flash press the sensor into its socket using a soft cloth then reboot the device The Model TS200 boots up and is ready for configuration see the Configuration section or...

Page 6: ...and time see Table 4 5 Configure all settings and click APPLY CHANGES AND RESTART The unit reboots with the configured settings NOTE If the network mode is DHCP but no DHCP server exists the unit fal...

Page 7: ...rts after the measured temperature drops below the threshold temperature 0 100 5 seconds Offset The value to add to or subtract from the temperature measured by the TempSense 10 to 10 F 0 F 6 to 6 C 0...

Page 8: ...Pv4 address or FQDN string 0 0 0 0 time_zone The offset from UTC Select the offset from UTC using the roll box control Calibration 1 Place an object of known temperature in the field of view of the TS...

Page 9: ...rcent Allow the TS200 TS200W to operate in the testing environment for 10 30 minutes to adjust to its environment before scanning personnel Subject Preparation To obtain accurate skin temperatures ens...

Page 10: ...andard IOMs Current Release 42004 Instr Manuals 42004 566A docx 03 21 Specifications Electrical Power TS200 PoE TS200W 120 V ac Mechanical Dimensions 7 26 H 5 76 W 1 5 D in 184 4 146 3 38 1 mm Weight...

Reviews: