INSTALLATION, OPERATION & 

MAINTENANCE DATA SHEET 

SERIES SJIC and SJICH JUNCTION BOXES 

Increased Safety Terminal Enclosures For Use In 

Zone Classified Hazardous Locations

 

 

P/N KIL00921446 FORM NO. K1446  R6/18  ECO-2-045-18   
 

 

 

 

Page 8 of 

10

 

METAL ENCLOSURES  

FIGURE 1 -  SJIC  (SCREW COVER) -  (See Table 2 below) 

 

 Note:      The maximum hole size for an enclosure wall using the "A" dimension and for boxes with a nominal 

depth of 3" (76mm) =  1-1/2" NPT (M40), with a nominal depth of 4" (102mm) = 2" NPT (M50), with a nominal 

depth of 5" (127mm) = 2-1/2" NPT (M63) and with a nominal depth of 6" (152mm) = 3-1/2" NPT (M80) .

 

 

TABLE 1  -   SJIC  OVERALL  DIMENSION  CHART 

 

 

Catalog 

Number 

Height 

in. (mm) 

Width 

in. (mm) 

Depth 

in. (mm) 

"E" 

"F"

 

"A" Blank 

Wall Area 

"B" Blank 

Wall Area

 

"C" Blank 

Wall Area 

"D" Blank 

Wall Area

 

SJIC 040403 

4 (102) 

4 (102) 

3 (76) 

2 .00 (51) 

4.75 (121) 

 

3.13 (79) 

3.13 (79) 

1.19 (30) 

SJIC 060403 

6 (152) 

4 (102) 

3 (76) 

2 .00 (51) 

6.75 (171) 

 

5.13 (130) 

3.13 (79) 

3.19 (81) 

SJIC 040404 

4 (102) 

4 (102) 

4 (102) 

2 .00 (51) 

4.75 (121) 

2.47(63) 

3.13 (79) 

3.13 (79) 

1.19 (30) 

SJIC 060404 

6 (152) 

4 (102) 

4 (102) 

2 .00 (51) 

6.75 (171) 

2.47(63) 

5.13 (130) 

3.13 (79) 

3.19 (81) 

SJIC 060604 

6 (152) 

6 (152) 

4 (102) 

4.00 (102) 

6.75 (171) 

2.47(63) 

5.13 (130) 

5.13 (130) 

3.19 (81) 

SJIC 060606 

6 (152) 

6 (152) 

6 (152) 

4.00 (102) 

6.75 (171) 

4.47 (114) 

5.13 (130) 

5.13 (130) 

3.19 (81) 

SJIC 080606 

8 (203) 

6 (152) 

6 (152) 

4.00 (102) 

8.75 (222) 

4.47 (114) 

7.13 (181) 

7.13 (181) 

5.19 (132) 

SJIC 080804 

8 (203) 

8 (203) 

4 (102) 

6.00 (152) 

8.75 (222) 

2.47(63) 

7.13 (181) 

7.13 (181) 

5.19 (132) 

SJIC 080806 

8 (203) 

8 (203) 

6 (152) 

6.00 (152) 

8.75 (222) 

4.47 (114) 

7.13 (181) 

7.13 (181) 

5.19 (132) 

SJIC 100804 

10 (254) 

8 (203) 

4 (102) 

6.00 (152) 

10.75 (273) 

2.47(63) 

9.13 (232) 

7.13 (181) 

7.19 (183) 

SJIC 100806 

10 (254) 

8 (203) 

6 (152) 

6.00 (152) 

10.75 (273) 

4.47 (114) 

9.13 (232) 

7.13 (181) 

7.19 (183) 

SJIC 101006 

10 (254) 

10 (254) 

6 (152) 

8.00 (203) 

10.75 (273) 

4.47 (114) 

9.13 (232) 

9.13 (232) 

7.19 (183) 

SJIC 121005 

12 (305) 

10 (254) 

5 (127) 

8.00 (203) 

12.75 (324) 

3.47 (88) 

11.13 (283) 

9.13 (232) 

9.19 (233) 

SJIC 121006 

12 (305) 

10 (254) 

6 (152) 

8.00 (203) 

12.75 (324) 

4.47 (114) 

11.13 (283) 

9.13 (232) 

9.19 (233) 

SJIC 121206 

12 (305) 

12 (305) 

6 (152) 

10.00 (254) 

12.75 (324) 

4.47 (114) 

11.13 (283) 

11.13 (283) 

9.19 (233) 

SJIC 141206 

14 (356) 

12 (305) 

6 (152) 

10.00 (254) 

14.75  (375) 

4.47 (114) 

13.13 (334) 

11.13 (283) 

11.19 (284) 

SJIC 161406 

16 (406) 

14 (356) 

6 (152) 

12 (305) 

16.75 (425) 

4.47 (114) 

15.13 (384) 

13.13 (334) 

13.19 (335) 

 

Summary of Contents for Killark SJIC

Page 1: ... or death IMPORTANT Please read these instructions carefully before installing or maintaining this equipment Good electrical practices should be followed at all times and this data should be used as a guide only Technical information advice and recommendations contained in these documents is based upon information that Killark believes to be reliable All the information and advice contained in the...

Page 2: ...ked ambient on the nameplate e A 1 4 20 UNC M6 ground earthing stud is supplied on all Series SJICH and SJICH stainless steel enclosures f To maintian proper IP ratings be sure to follow all mfr s mounting instructions when installing certified cable glands or conduit entries Warning Enclosures must be installed in the upright vertical position only Mounting the enclosures in a horizontal position...

Page 3: ...ed etc per EN 60079 7 The operating service temperature of the enclosure is limited to the temperature of the gland fitting if less than the enclosure h Killark KDE series drain and breather may be installed The operating temperature of the enclosure is limited to the temperature of the drain and breathers if lower than the enclosure s Other drain and breathers may be installed the user is respons...

Page 4: ...ll be suitable for exceed the minimum ambient and maximum temperature defer to T Code achieved in service All conductors shall be sized per the National or Local Electrical Codes for the max continuous current or max motor load of the installation h Conductors at entry points may reach 73o C in a 55o C ambient and may reach 108o C in a 90o C ambient See Note j below i Only the terminal blocks list...

Page 5: ...52U IECEx FTZU 10 0011U 50o C Klemsan Elektrik PUK Screw FTZU 09ATEX0252U IECEx FTZU 10 0011U 50o C Klemsan Elektrik PYK Cage clamp FTZU 09ATEX0252U IECEx FTZU 10 0011U 50o C ABB ZS Screw LCIE 08ATEX0007U IECEx LCI 08 0031U 50o C ABB ZK Cage clamp LCIE 13ATEX3042U IECEx LCI 13 0025U 50o C WAGO 2001 Cage clamp PTB 05ATEX1094U IECEx PTB 11 0093U 50o C WAGO 2002 Cage clamp PTB 03ATEX1162U IECEx PTB 0...

Page 6: ...9 7 ANSI ISA 60079 7 CSA 60079 31 ANSI ISA 60079 31 CSA No 94 1 94 2 No 14 UL50 UL50E UL508 CSA 60529 ANSI IEC 60529 IEC ATEX Certifications ATEX Ratings SIRA 14 ATEX 3157 0518 II 1 G Ex ia IIC T6 T5 T4 Ga II 2 D Ex tb IIIC T80o C T100o C T130o C Db IP66 OR 0518 II 2 G Ex eb IIC T6 T5 T4 Gb Ex ib IIC T6 T5 T4 Gb II 2 D Ex tb IIIC T80o C T100o C T130o C Db IP66 OR 0518 II 1 G Ex eb ib IIC T6 T5 T4 ...

Page 7: ...onnection must be made in all circumstances Conduit Hubs and Cable Glands Conduit hubs and cable gland sizes may be mixed The maximum number of hubs or cable glands must be selected such that the walls are not weakened nor the enclosure stability affected See Figure 1 and 2 below and Tables 1 7 below for metal enclosure dimensions and mounting hole locations conduit and gland mountnig details usea...

Page 8: ... 75 121 2 47 63 3 13 79 3 13 79 1 19 30 SJIC 060404 6 152 4 102 4 102 2 00 51 6 75 171 2 47 63 5 13 130 3 13 79 3 19 81 SJIC 060604 6 152 6 152 4 102 4 00 102 6 75 171 2 47 63 5 13 130 5 13 130 3 19 81 SJIC 060606 6 152 6 152 6 152 4 00 102 6 75 171 4 47 114 5 13 130 5 13 130 3 19 81 SJIC 080606 8 203 6 152 6 152 4 00 102 8 75 222 4 47 114 7 13 181 7 13 181 5 19 132 SJIC 080804 8 203 8 203 4 102 6...

Page 9: ... Blank Wall Area D Blank Wall Area E Blank Wall Area SJICH 060604 6 152 6 152 4 102 4 00 102 6 75 171 2 47 63 5 13 130 5 13 130 3 19 81 1 81 46 SJICH 060606 6 152 6 152 6 152 4 00 102 6 75 171 4 47 114 5 13 130 5 13 130 3 19 81 3 81 97 SJICH 080606 8 203 6 152 6 152 4 00 102 8 75 222 4 47 114 7 13 181 7 13 181 5 19 132 3 81 97 SJICH 080804 8 203 8 203 4 102 6 00 152 8 75 222 2 47 63 7 13 181 7 13 ...

Page 10: ...BLE 7 Minimum Distance From Center Line to Center Line of Conduit Cable Entries NPT Metric 4 3 1 2 3 M75 2 1 2 M63 2 M50 1 1 2 M40 1 1 4 M32 1 M25 3 4 M20 1 2 M16 IN mm 2 3 4 70 2 1 2 64 2 51 2 51 1 5 8 41 1 3 8 35 1 1 4 32 1 25 7 8 22 3 4 19 NPT Metric 4 3 1 2 3 M75 2 1 2 M63 2 M50 1 1 2 M40 1 1 4 M32 1 M25 3 4 M20 1 2 M16 IN mm 3 1 4 83 3 76 2 3 4 70 2 1 2 64 2 1 8 54 1 7 8 48 1 3 4 44 1 1 2 38 ...

Reviews: