INSTALLATION, OPERATION &  

MAINTENANCE DATA SHEET 

 

SERIES VSIH                

ATTACHMENT PLUGS 

 

 

P/N KIL00921520  FORM NO. K1520  R07/21  ECO-7-012-21

 

 

 

 

 

 

 

 

Page 

1

 of 

7

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

INERIS 20 ATEX 0022X        

Ex eb IIC T3

…T6

 

Gb

 

    IECEx INE 20.0020X   

       Ex tb IIIC T80

o

C Db  IP66 

                                             CML 21UKEX1362X

 

CAUTION

:

 

Before installing, make sure you are compliant with area classifications, as failure to do so may result in bodily injury, death and property damage. Do 
not attempt installation until you are familiar with the following procedures. All installation must comply with the applicable Electrical Code(s). 

Make sure that the circuit is de-energized before starting installation or maintenance.   

Verify that the installation is grounded.  Failure to ground will create electrical shock hazards, which can cause serious injury and or death. 

IMPORTANT: 

Please read these instructions carefully before installing or maintaining this equipment. Good electrical practices should be followed at all times and this 
data should be used as a guide only. 

Technical information, advice and recommendations contained in these documents is based upon information that Killark believes to be reliable. All the 
information and advice contained in these documents is intended for use only by persons having been trained and possessing the requisite skill and 
know-how and to be used by such persons only at their own discretion and risk. The nature of these instructions is informative only and does not cover 
all of the details, variations or combinations in which this equipment may be used, its storage, delivery, installation, check out, safe operation and 
maintenance.  Since conditions of use of the product are outside of the care, custody and control of Killark, the purchaser should determine the 
suitability of the product for his intended use, and assumes all risk and liability whatsoever in connection therewith. 

 

16A, 32A, 63A and 125A EXPLOSION-PROOF AND DUST 

IGNITION-PROOF ATTACHMENT PLUGS - 

SERIES VSIH

 

Summary of Contents for KILLARK VSIH Series

Page 1: ...hese instructions carefully before installing or maintaining this equipment Good electrical practices should be followed at all times and this data should be used as a guide only Technical information...

Page 2: ...rk A Division of Hubbell Inc Delaware 2112 Fenton Logistics Park Blvd Fenton Missouri 63026 USA INSTALLATION OPERATION MAINTENANCE DATA SHEET SERIES VSIH ATTACHMENT PLUGS P N KIL00921520 FORM NO K1520...

Page 3: ...nce of the material to the surroundings is assured NO modifications are allowed to Series VHIS devices which are not specifically described in this instruction manual When installing Series VHIS devic...

Page 4: ...mbient temperature is 60oC Tcable 90oC for Series VSIH63 when max ambient temperature is 60oC Tcable 85oC for Series VSIH125 2 2 TYPES OF PROTECTION ATEX Certificate INERIS 20 ATEX 0022X IECEx Certifi...

Page 5: ...k 125P405 50 60 380 440 Red 3 20R403 32R403 63R403 Black 125R403 3P E 100 300 50 690 Red 10 20P410 32P410 63P410 Black 125P410 3P E 300 500 50 690 Red 2 20P402 32P402 63P402 Black 125P402 3P N E 50 60...

Page 6: ...the warranty provision No changes to the plug impairing its explosion protection are permitted Install and operate the plug only if it is clean and undamaged 5 2 ACCESSORIES Protection Cup Only approv...

Page 7: ...NG 6 1 ROUTINE MAINTENANCE Routine maintenance is required to guarantee the efficiency of the enclosure and to maintain the required level of protection 1 Check that the sealing ring is in place and n...