Hubbell Premise Wiring, HUBBELL INCORPORATED (Delaware)
14 Lord's Hill Rd, Stonington CT 06378 (800) 626-0005, Fax (860) 535-8328
www.hubbell-premise.com
Control No.
Page
of
Rev. Date:
Hubbell Premise Wiring Instruction Sheet
®
Control No.
Page
of
Rev. Date:
STEP 1:
A)
Locate airfl ow directional arrow imprinted on outside of fan
housing. Arrow indicates direction of airfl ow. Arrow should
point up, when assembling, to ensure air intake into cabinet
as shown in Fig. 1.
B)
Power cord (item11) can be used by either side wiring to
receptacle or by terminating with two prong plug (supplied).
1) For side wiring assemble grommet/strain relief
(item 13) to power cord (item 11) as shown in Fig. 2.
2) For terminating with two prong plug assemble plug
(item 12) to power cord (item 11) as shown in Fig. 3.
Fig. 2
Fig. 3
13
12
11
11
77877301
1
4
F
22JAN04
77873301
4
4
F
22JAN04
FAN ACCESSORY
PARTS LIST: REKF, REKFF
Item
Description
Qty
1
Fan
1
2
Wire, Fan Guard
2
3
Lock
Nut
4
4
Rubber
Washer
4
5
Fan
Bracket
1
6
Fan Bracket Spacer
1
7
#6-32 x 2" Pan Head Screws
4
8
#6-32 x 2" Flat Head Screws
4
9 Adhesive
Air
Baffl es
1
10
Foam
Plenums
2
11
Power
Cord
1
12
AC Plug
1
13
Grommet / Strain Relief
1
(For
1/2"
Knockout)
14
Filter
Bracket
1
15
Filter
2
16
3"
Foam
4
Notes:
Please read entire instructions before assembling.
Compare contents with above parts list to ensure that you
have received all parts.
Use door seal/gasket kit (HPW catalog #REKG) to enhance
performance of fan.
Use Rebox power kit (HPW catalog #REKP) to prepare
Rebox for power.
2
4
4
1
5
12
DIRECTION
OF AIR FLOW
REKFF
This instruction sheet applies to the following Hubbell Premise Wiring (HPW) catalog numbers:
REKF FAN KIT
REKFF
FILTER
KIT
Direction of Air Flow
Fig. 1
1
2
3
5
10
9
8
7
12
13
4
11
6
5
14
15
16
12
Hubbell Premise Wiring, HUBBELL INCORPORATED (Delaware)
23 Clara Dr Mystic, CT 06355 (800) 626-0005, Fax (860) 535-8328
www.hubbell-premise.com