Betriebsanleitung ACS-1000
Rev. 1.0 - 08/12
Hubitron Steuerungstechnik
Hubitron Steuerungstechnik, Hauptstr. 4/1, D-89611 Obermarchtal, Tel. +49(0)7375/922066, FAX +49(0)7375/922077
Seite 5 von 14
The ACS-1000 must be mounted level on the
machine slide. Best, check the levelness with a
mason’s level.
8.1.2 Arrangement
•
delete compensation data:
switch on the unit
main menu -
-
-
•
activate laser:
in the main menu push
•
position machine at the left outer stop
•
set up reflection area (i.e. white sheet of paper
DIN A4)
•
position machine at the right outer stop
•
arrange ACS-1000 that the laser beam remains
within the reflection area
A sideways deviation can be corrected by turning
the ACS-1000 on the mounting plate. The 4 screws
underneath the housing blinds have to be loosened
with the provided pin spanner SW4.
8.2 Wire spanning and arranging
For measuring we recommend an erode wire with a
diameter of 0.2 to 0.3 mm.
•
fix the wire on both machine ends in about the
same height
•
position machine slide that the wire runs through
the sensor head and a value within ± 1 mm is
displayed
The measuring range of the sensor head lays in the
bottom quarter:
•
set display data to 0 (
)