CAUSE (S)
The factory does not fully tighten these clamps to ensure longer life. There is an
orange tag on the side of unit that says hose clamps should be tightened.
SOLUTION (S)
Tighten clamps with screwdriver.
PROBLEM 11 “A, B”
Unit works prop
erly but the tank starts to collapse, you can’t unscrew to pull the
cap off the unit. It seems to have created a vacuum.
CAUSE (S)
The vent hole in the cap has become clogged with dirt and is not allowing air into
the tank.
SOLUTION (S)
Take a small wire and push in through the vent hole. This will allow air into the
tank and release the vacuum. Take cap off, clean vent hole, clean check valve,
oil valve & reinstall.
PROBLEM 12 “C, B”
Pump module on SVV & stainless; when you are pumping your unit, some fluid is
com-ing back up thro-ugh the pump.
CAUSE (S)
The small plug at the top of the pump module has deteriorated due to chemical
attack.
SOLUTION (S)
Pull out the small check (antenna with o-ring) and replace with new unit.
PROBLEM 13 “C, D”
Pump module; when pumping the unit slips and does not seal properly to push
air into unit.
CAUSE (S)
The rubber or leather check inside pump has dried out or has cracked.
SOLUTION (S)
Take top off pump module and check seal. If cracked, replace. If dry, place
some lubricating grease on seal.