1022410 – 0001 Rev. 2
3–66 UMOD hardware theory of operation
•
Simultaneous loopback (see figure 3-41). This loopback
configures one of the UMODs to perform a near and far
loopback test. If the UMOD at the far end of the link is set
to perform a far loopback, the combined tests will verify
functioning of all components in the communications link.
Figure 3-41
Simultaneous loopback
TX Digital
RX Digital
TX IF
RX IF
TX
RX
DTE
TX
RX
UMOD
TERRESTRIAL DATA
INTERFACE
The BERT function, in combination with the loopback tests,
enables the user to test various UMOD components. The BERT
function consists of an independent transmit pattern generator and
a receive error analyzer. Transmit BERT pattern generator
parameters are as follows:
•
Industry-standard 511-bit m-length pseudo-random
sequence
•
8-bit user-entered repetitive pattern
•
All l’s
•
All 0’s
•
1010... repetitive
•
6-bit user-entered repetitive pattern
•
Insert a single error
The BERT error analyzer works with the pattern generator at the
transmit end. Methods for evaluating error patterns are as follows:
•
Bit error rate
•
Average bit error rate
•
Block error rate
•
Sync loss
The BERT receive analyzer consists of a 2
28
- 1 bit counter, a 2
28
-
1 bit error counter, a 2
17
- 1 block counter, and a 2
17
- 1 block
error counter.
BERT description