background image

 

BA 879 410-led HM; DE, GB - 23642 - 2016.05-V01 

Hugo Müller GmbH & Co KG

Sturmbühlstraße 145-149

D-78054 VS-Schwenningen

Tel.: +49 (0) 7720 80 836

Fax: +49 (0) 7720 31 083

info@hugo-mueller.de

www.hugo-mueller.de 

 

 

 

INSTRUCTION MANUAL TRIAC DIMMER [R,L] – 879 410 LED

 

Operating modes 

Operating modes 

Operation with 

pushbutton

 

 

Pressing the pushbutton shortly turns the load on and off. 

 

Pressing the pushbutton for a long time carries-out a cyclical dimming (as long as the 

pushbutton is pressed). 

In this operation mode the internal potentiometer defines the lower dimming limit (pushbutton         

MEM, NO MEM or MEM PLUS). It avoids flickerings or undesired switching-offs. 

 
Operation with 

external potentiometer 

(galvanically isolated) 

 

It is possible to control the load with a 10 k

 potentiometer. 

 

At the minimum level of the potentiometer the load stays turned off. 

 

By turning the potentiometer, the load increases. 

 

It is necessary to set the built-in potentiometer at minimum.

 

 

Operation with 

internal potentiometer 

 

It is possible to control the load with the internal potentiometer of the dimmer. 

 

By setting the potentiometer to the minimum value, the use of an external potentiometer is 

possible.  

 

If you put the potentiometer to any value higher than the minimum value, the potentiometer 

will only consider this value. It will ignore the signals of the external potentiometer. 

 Operation with 

signal 0 - 10V

 (galvanically isolated) 

 

0V correspond to a switched off status. 

 

10V correspond to the maximum illumination of the dimmer. 

You can use any external, isolated or not isolated voltage source 

with 0 - 10 V (SPS, control panel etc.). 
 
In this mode of operation the internal potentiometer defines the minimum dimming level. It avoids 
flickerings or undesired switching-offs. 
 

Master-Slave

-configuration (galvanically isolated) 

This configuration is used, if the maximum load that is supported by one dimmer is exceeded. With 

this configuration it is possible to distribute the load across multiple dimmers and extend the load. For 

this it is necessary to spread the load into several partial loads with each dimmer controlling its 

maximum load. It is also recommended to use slaves in applications where different loads have to be 

controlled. In this mode of operation the internal potentiometer defines the minimum dimming level. It 

avoids flickerings or undesired 

switching-offs. 

 

 

Example  1

 

Example  2

 

Example  3 

Example  4 

Example  5

 

Operation with pushbutton 

Place the selector switch in the 

desired working mode: 

 

MEM

 to switch on at the 

same level as turned off. 

 

NO MEM

 to switch on 

with maximum power. 

 

MEM PLUS

 to switch on 

at the same level as 

turned off and to rebuild 

the operating status (turn 

on/ off or level of 

intensity) after power 

failure. 

Operation with pushbutton, extended by 

    slaves 

 

The MASTER dimmer must be set 

according to example 1.To configure a 

dimmer as SLAVE, the selector switch 

must be in SLAVE mode.  

 

It is possible to add an unlimited number 

of slaves. 

 

There can be a time delay in the 

response if you use a large number of 

salves. 

 

The heat development in the installation 

box has to be monitored, especially when 

using a larger number of dimmers. 

 

It is recommended to realize a spacing 

between each dimmer (1 module 

spacing). 

Operation with potentiometer 

 

The selector switch must be in the 

correct position for the 

potentiometer 

 

The brightness level depends on the 

position of the potentiometer. 

 

Turning the potentiometer clockwise 

will increase the light intensity. 

A)

 

Operation with ext. potentiometer 

B)

 

Operation with int. potentiometer 

Operation with 0 - 10V 

signal 

 

The selector switch 

must be in the 

correct position 0 - 

10V. 

 

Level 0V 

corresponds to the 

status switched off. 

The light intensity 

increases in the 

same amount as the 

voltage does to 10V. 

3-phase-installation controlled by potentiometer 

and increased by slaves 

 

Do the installation according to the wiring diagram. 

 

The MASTER dimmer must be configured as in 

example 3A. The slaves must be in position SLAVE.  

 

It is recommended to distribute the loads between 

the three phases. 

 

In case of three-phase line without electrical neuter, 

please contact us. 

 

Reviews: