41
12. Errors
If something is wrong on the main components of the Pendel, the Pendel will stop or not
start up. Underneath is a list of error and their causes and solutions:
PROBLEM
CAUSE
ACTION
Pendel won’t
lift
off
off
off
main fuse is blown
replace main fuse
off
off
off
height switch broken replace height switch
off
off
off
fuse PCB broken
replace PCB fuse
on
on
on
relay clicks, fuse
compressor broken
replace compressor
fuse
on
on
on
relay doesn’t click
relay is broken
replace relay of the
compressor
on
on
on
compressor runs,
release switch is still
open.(hissing sound)
close release switch
7 x
on
on
battery empty
charge batteries
Pendel is up
but won’t drive
off
off
off
Main fuse is blown
replace main fuse
off
off
off
Safety switch is still
active
switch safety switch
off
off
off
off
fuse PCB broken
replace fuse PCB
off
off
on
error in electronics
contact your dealer
on
off
on
no click > main relay
broken
replace main relay
on
off
on
no click, PCB broken replace PCB
on
off
on
brake lights on,
braking lever not
activated, broken
brake switch
replace brake switch
2x
off
on
throttle is active
check throttle
7x
off
on
battery empty
charge batteries
on
on
on
Pendel not in drive
position yet
lower Pendel, then
lift again.
lights, indicator,
or horn don’t
work
on
off
on
Fuse specific
function in fuse box
is blown
replace fuse of the
specific function
Pendel doesn’t
charge
no LEDs on charger
charger defect
replace charger
red LED on charger
charger not proper
connected to mains
reconnect charger to
mains
other errors
contact your local
huka dealer
If an error occurs, stop using the Pendel or drive at only lowest
possible speed and contact your local authorized huka dealer.
Summary of Contents for Pendel FD