5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor –HP05V080Y1 

 

7/18/2011                                

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Introduction 

 

 

Breathable Air Warning 

This compressor/pump is NOT equipped and should NOT be used “as is” to supply breathing quality air. 
For any application of air for human consumption, you must fit the air compressor/pump with suitable 
in-line safety and alarm equipment. This additional equipment is necessary to properly filter and purify 
the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association 
Commodity Specification G 7.1 – 1966, OSHA 29 CFR 1910. 134, and/or Canadian Standards Associations 
(CSA) 

DISCLAIMER OF WARRANTIES 

In the event the compressor is used for the purpose of breathing air application and proper in-line safety 
and  alarm  equipment  is  not  simultaneously  used,  existing  warranties  are  void,  and  EMAX  Air  Force 
Technology disclaims any liability whatsoever for any loss, personal injury or damage.

 

 

 

 

 

DANGER

!

 

CALIFORNIA PROPOSITION 65 

 

This product or its power cord may contain chemicals known to the state of 
California  to  cause  cancer  and  birth  defects  or  other  reproductive  harm. 
Wash hands after handling. 

 

WARNING! 

 

READ INSTRUCTION MANUAL BEFORE OPERATING 

 

RISK  OF  FIRE  OR  EXPLOSION

  –  DO  NOT  SPRAY 

COMBUSTIBLE/FLAMMABLE  LIQUID  IN  A  CONFINED 
AREA. SPRAY AREA MUST BE WELL VENTILATED. DO 
NOT  SMOKE  WHILE  SPRAYING  OR  SPRAY  WHERE 
SPARK OR FLAME IS PRESENT. ARCING PARTS – KEEP 
COMPRESSOR  AT  LEAST  20  FEET  AWAY  FROM 
SPRAYING AREA AND ALL EXPLOSIVE VAPORS. 

 

RISK  OF  INJURY

  –  DO  NOT  DIRECT  AIR  STREAM  AT 

BODY.  USE  EYE  PROTECTION.  COMPRESSOR  STARTS 
AUTOMATICALLY.  MOVING  PARTS.  DO  NOT  TOUCH. 
KEEP  GUARDS  IN  PLACE.  COMPRESSOR  DOES  NOT 
SUPPLY BREATHABLE AIR. 

 

RISK  OF  BURSTING

  –  DO  NOT  ADJUST  REGULATOR 

TO  RESULT  IN  OUTPUT  PRESSURE  GREATER  THAN 
MARKED  MAXIMUM  PRESSURE  OF  ATTACHMENT.  IF 
A REGULATOR HAS NOT BEEN INSTALLED - 

 

 

USE  ONLY  ATTACHMENT  RATED  AT  200  PSI  OR 
HIGHER.  DO  NOT  WELD  ON  OR  REPAIR  TANK  – 
REPLACE. DO NOT OPERATE WITHOUT PROPER ASME 
SAFETY VALVE IN PLACE. 

 

RISK OF ELECTRICAL SHOCK

 – HAZARDOUS VOLTAGE: 

DISCONNECT  FROM  POWER  SOURCE  BEFORE 
SERVICING.  COMPRESSOR  MUST  BE  GROUNDED.  DO 
NOT  USE  GROUNDING  ADAPTORS.  DO  NOT  EXPOSE 
TO RAIN. STORE INDOORS. 

IF  CONNECTED  TO  A  CIRCUIT  PROTECTED  BY  FUSES,  USE 
TIME-DELAY FUSE MARKED “D” 

COMPLIES WITH CCR462 (L)(2). 

DO  NOT  USE  BELOW  GARAGE  FLOOR  OR  GRADE 
LEVEL 

DRAIN  TANK  EVERYDAY  TO  PREVENT  CORROSION  AND 
POSSIBLE INJURY DUE TO TANK DAMAGE 

 

 

 

 

Summary of Contents for HP05V080Y1

Page 1: ...5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor HP05V080Y1 7 18 2011 1 HULK COMPRESSOR Operating Manual Model HP05V080Y1...

Page 2: ...ts or other reproductive harm Wash hands after handling WARNING READ INSTRUCTION MANUAL BEFORE OPERATING RISK OF FIRE OR EXPLOSION DO NOT SPRAY COMBUSTIBLE FLAMMABLE LIQUID IN A CONFINED AREA SPRAY AR...

Page 3: ...he intake filter should be installed at the end of the pipes with a hood to protect them from the elements Special size filters are required for pipe away If the compressor has to be located where the...

Page 4: ...voltage correspond to the motor nameplate and starter A 230 volt motor will not work sufficiently on a nominal 208 volt system Even if the actual voltage is up to 208 volts the 10 12 volt drop during...

Page 5: ...sight glass Turn the compressor over a few revolutions by hand to make sure that everything is free Check belt tension should be of play Remove rags tools and any other objects from the vicinity of th...

Page 6: ...an be installed without damage or strain Overtime belts stretch and it is recommended that all belts be changed at the same time To adjust the belts loosen the four motor frame nuts and adjust the sin...

Page 7: ...twork in the building is 208 volts order a 208 volt motor If the starting voltage is much less the 90 of the motor nameplate voltage the motor cannot be expected to start and the interior building wir...

Page 8: ...5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor HP05V080Y1 7 18 2011 8 APP3Y0521T...

Page 9: ...5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor HP05V080Y1 7 18 2011 9...

Reviews: