5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor –HP05V080Y1 

 

7/18/2011                                

In  order to  receive  maximum  performance  and  long  life from  your  compressor,  the  following 
instructions should be read carefully and all points regarding installation and operation of the 
unit should be noted and observed. Carefully reading this manual before connecting anything 
to the motor or compressor is necessary for optimum trouble-free operation. 

Inspection 

Check for possible damage from transit and test the pulley by turning it freely with your hands. 

Report any damage to the delivery carrier immediately. 

Location 

Select a clean, dry, and well-lit location. In cold climates, the compressor should be installed in 
a  heated  building.  Insulate  cold  water  or  other  low  temperature  pipes  that  pass  overhead  to 
avoid possible collection and dripping of condensate onto the compressor and motor that could 
cause rust and/or motor shorting. 

Do not 

install the compressor in a boiler room, paint spray 

room, or area where sandblasting occurs. If acid or dust is in the air where the compressor is 
operating,  the  compressor  intake  should  be  piped  to  the  outside.  This  intake  pipe  should  be 
increased one pipe size for every twenty (20) feet of run and the intake filter should be installed 
at the end of the pipes with a hood to protect them from the elements. 

Special size

 filters are 

required for pipe away. 

If the compressor has to be located where the motor will be exposed to appreciable quantities 
of water, oil, dirt, acid, or alkaline fumes, the motor must be of special construction to avoid 
rapid deterioration; i.e. TEFC 

Unless the base is exactly level, shims will probably be required. Any space between base and 
foot  should  be  shimmed  rather  than  drawing  the  foot  down  thus  placing  strain  on  the  unit. 
When unit is properly shimmed, vibration will be at a minimum. 

Allow  sufficient  space  around  the  compressor  so  that  it  is  accessible  from  all  sides  for 
maintenance.  Mount  the  unit  with  the  pulley  towards  the  wall  at  least  18  inches  between 
pulley & wall. 

POWER SUPPLY AND WIRING 

 

Installation should be executed by a licensed electrician 

 

All  electrical  connections  must  be  tightened  before  starting.  This  includes 
connections  at  the  motor  junction  as  well  as  the  Condor  Switch  or  Magnetic 
starter.  This  shall  include  all  factory  connections.  Repeat:  Check  all  electrical 
connections before startup. 

Wiring  should  be  installed  by  a  licensed  electrician  who  is  familiar  with  requirements  of  the 
National Board of Fire Underwriters and of the local inspectors is recommended. Consult your 
local electrical contractor regarding electric codes and recommended wire sizes. 

Single Phase Motors: 

Summary of Contents for HP05V080Y1

Page 1: ...5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor HP05V080Y1 7 18 2011 1 HULK COMPRESSOR Operating Manual Model HP05V080Y1...

Page 2: ...ts or other reproductive harm Wash hands after handling WARNING READ INSTRUCTION MANUAL BEFORE OPERATING RISK OF FIRE OR EXPLOSION DO NOT SPRAY COMBUSTIBLE FLAMMABLE LIQUID IN A CONFINED AREA SPRAY AR...

Page 3: ...he intake filter should be installed at the end of the pipes with a hood to protect them from the elements Special size filters are required for pipe away If the compressor has to be located where the...

Page 4: ...voltage correspond to the motor nameplate and starter A 230 volt motor will not work sufficiently on a nominal 208 volt system Even if the actual voltage is up to 208 volts the 10 12 volt drop during...

Page 5: ...sight glass Turn the compressor over a few revolutions by hand to make sure that everything is free Check belt tension should be of play Remove rags tools and any other objects from the vicinity of th...

Page 6: ...an be installed without damage or strain Overtime belts stretch and it is recommended that all belts be changed at the same time To adjust the belts loosen the four motor frame nuts and adjust the sin...

Page 7: ...twork in the building is 208 volts order a 208 volt motor If the starting voltage is much less the 90 of the motor nameplate voltage the motor cannot be expected to start and the interior building wir...

Page 8: ...5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor HP05V080Y1 7 18 2011 8 APP3Y0521T...

Page 9: ...5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor HP05V080Y1 7 18 2011 9...

Reviews: