7
3. Technical data
3.1 General
Measurement range
0.2–100 m*
Accuracy
± 1.5 mm**
Unit of measurement
m, in, ft, ft+in
Laser class
2
Laser type
635 nm, < 1 mW
Protection rating
IP 54
Laser auto-shutdown
30 h
Instrument auto-shutdown
180 s
Operations per charge
up to 5000 measurements***
Battery type
3 x 1.2 V Ni-Mh battery (3 x 850 mAh)
Operating temperature
0–40°C
Storage temperature
-10–60°C
Dimensions H x W x L
115 x 50 x 25 mm
Weight with batteries
110 g
*when measuring a target with 100% reflectivity (e.g. a painted white wall), with low backlight and an operating temperature of 25°C
**this degree of precision applies when measuring distances of between 0.2 and 10 m; when measuring distances of between 10 m and 100 m, the maximum
tolerance may decrease by 0.1 mm/m
***when used at room temperature