Summary of Contents for ECOFRIDGE DISPLAY

Page 1: ...HULTSTEINS CONTROL PANEL ECOFRIDGE DISPLAY USER MANUAL 1 0 Stopped START SET P MENU STOP 2018 12 12 14 09 Boxtemp Set p 22 STOP ...

Page 2: ...ucing transport refrigeration with hydraulics was totally unique and since then we have continued to drive the market forward with innovative solutions The result is reliable fuel efficient and environmentally friendly refrigeration units which provide maximum customer benefit on the road ...

Page 3: ...PRODUCT OVERVIEW 4 MENU SELECTION 5 BYTA SPRÅK CHANGE LANGUAGE 5 OPERATING INFORMATION 6 NORMAL OPERATION 7 ERRORS AND WARNINGS 8 PANEL SETTINGS 10 MENU SYSTEM 11 TWO ZONE UNIT MENU 13 CONTENTS ...

Page 4: ...ENU STOP Box Temp Set p 22 On Off Only vehicle operation Start operation Change desired temp Stop operation Cooling DEFR Box temp SET P MENU STOP Set p 22 2020 02 12 14 09 Current status symbol Current status text Extra status info Displayed value actual value Text fields for menu buttons Name of displayed value Set value ...

Page 5: ...ct to a PC to perform software updates or read the log BUTTONS FOR MENU SELECTION The five buttons under the display are used to control what is shown on the display and to adjust the various settings The function of the buttons is displayed in the small text fields above the buttons The button with the red border at the far right is always used to stop or cancel the current operation TO AND FROM ...

Page 6: ... of the actual value The text and numeric values vary depending on what is being controlled In the example below this is Box and the set value in other words the set value you wish to achieve DATE AND TIME The date and time is used for the internal logging function It is therefore important that the clock is set correctly TEXT FIELDS FOR MENU BUTTONS The button used to enter the menu and some shor...

Page 7: ...02 12 14 09 Stopped No contact When this symbol is displayed the unit switches to cooling mode The symbol will illuminate while cooling is in progress Cooling COOLING When this symbol is displayed the unit switches to heating mode The symbol will illuminate while heating is in progress Heating HEATING When this symbol is displayed the unit switches to defrosting mode The symbol will illuminate whe...

Page 8: ...y displayed alternating with the normal function symbol Some errors detected by the system do not force operation to be stopped This could be due to the fact that it is a temporary error or a error which does not affect the current process The user does not need to take any action immediately but a warning is displayed If you receive a warning or error notification follow the information on the sc...

Page 9: ... falls you must enter the menu manually to close the error message Do this by pressing the ERROR or MENU button 2020 02 12 14 09 Operating error BACK UPP NER STOP Boxtemp Bör 22 OK STOPPED HIGH PRESSURE 2020 02 12 14 09 Op MENY FEL STOPP Boxtemp Bör 22 CONF STOP BACK Pressure error High pressure on pressure side Contact service workshop 2020 02 12 14 09 Op MENY FEL STOP Boxtemp Bör 22 STOP BACK No...

Page 10: ...r decrease the set value SAVE Press the SAVE button to send the new value to the system CANCEL The CANCEL button leaves the window without sending anything to the system The old setting remains TWO ZONE UNIT For models with 2 zones two temperatures and two symbols are displayed These are called Box 1 and Box 2 Box 1 is generally the master unit and Box 2 is the slave In the case of unit HS215 Box ...

Page 11: ...ANGE DOWN STOP Latest defr 1 2020 02 24 Set p 1 5 5 High pressure 17 2 BAR Low pressure 1 1 BAR Temperatures RPM 0 Rpm Plus from AC 0 1 V Battery voltage 26 5 V Phase sequence guard Running time daymotor 123 Hrs Running time nightmotor 35 Hrs Running time regulation 523 Hrs Latest service 2024 05 22 Mashine Refrigerant Spare parts Customer HUS version Hultsteins contact Options Display Password Wo...

Page 12: ...ore you contact service for support This can often help to rectify errors which are actually caused by one or more settings being set incorrectly in relation to the current operation DISPLAY LIGHTING AND CONTRAST are set locally in the display module They have an immediate effect You can manually set the brightness of the backlight display The system can switch off the backlight automatically to s...

Page 13: ...ement temp 2 25 2 Phase sequence Mains Disconnected Phase guard Inhibited Unit Type of refrig unit Refrig unit number Date delivered Year built Remark 1 Refrigerant Type of refrigerant Volume of refrigerant Limit high pressure Limit low high pressure Limit low pressure Limit defrost fan pause HUS version Spare parts Customer Hultsteins Contact Options Date 2020 02 24 15 58 Defr auto 1 On Defr auto...

Page 14: ...DIESEL FREE REFRIGERATION ...

Page 15: ...COOLNESS ON THE MOVE ...

Page 16: ...hultsteins com ...