44
www.humancaregroup.com
Reconditioning Manual (ENG)
To ensure that your walking aid is functioning
properly and safely, an annual inspection
should be done only by an authorized agent.
The following maintenance should be done
regularly:
Cleaning
In accordance with local regulations
where required, cleaning may be done
by industrial washing at 60 degrees for
10 minutes. Pressure washing must only
be done in a controlled environment
by professional cleaners. Do not
wash the bearings with a pressure
washer. Regular cleaning with a mild
liquid detergent or damp cloth is
recommended. DO NOT use any toxic
cleaning materials on the product as it
will damage it.
Wash only using an industrial
washer/sterilizer (see image)
Note! Do NOT use thinner, petrol or other
solvents.
Post treatment
Should cleaning be performed in an
industrial setting, ensure all connections,
spaces and holes are dried completely
before usage. Lubricate any moving
parts. For home cleaning (wiping with a
damp cloth), ensure the rollator is free
of residue moisture to avoid rusting its
components.
Finish
The rollator is painted and sealed for a
superior finish, however scratches can
occur with impact. Scratches in the
frame may result in corrosion.
Corrosive components
The rollator does contain components
that may rust if left in a moisture
setting. Periodically check all welding
points and screws. It is recommended
that an authorized agent perform this
inspection. If corrosion is present,
replace parts. If corrosion is extensive,
replace rollator.
Periodic inspections
At minimum, it is recommended that
an authorized agent perform an annual
inspection of the rollator and its
components to ensure it is functioning
as intended. Do not use the rollator
if any components are damaged or
inoperable. Have an authorized agent
perform necessary repair and/or
replacement.
Handle grip
Periodic replacement of the handle grip
may be necessary with usage. Replace
as required.
Braking system
The brakes should function in both the
control and park position and the wires
should be intact. Should these control
functions not operate as intended, cease
usage and immediately have the rollator
repaired.
Maintenance, inspection and testing
ENG
Summary of Contents for Carl-Oskar
Page 1: ...Carl Oskar Reconditioning Manual Rekonditioneringsanvisning Manuel de maintenance...
Page 3: ...www humancaregroup com 3...
Page 7: ...www humancaregroup com 7 Exploded View ENG 2 3 6 5 7 4 8 9 10 12 11 13 15 14...
Page 13: ...www humancaregroup com 13 Spr ngskiss SV 2 3 6 5 7 4 8 9 10 12 11 13 15 14...
Page 19: ...www humancaregroup com 19 Vue clat e FR 2 3 6 5 7 4 8 9 10 12 11 13 15 14...
Page 22: ...22 22 www humancaregroup com...
Page 23: ...www humancaregroup com 23...