HT-9500/HT-9500X Troubleshooting Guide

4. Reinsert the fuse holder into the power panel, then turn it 1/8 turn 

clockwise to secure it.

5. Plug the chair back into the wall outlet and turn it on.

6. Verify that the remote control LEDs now light.

Step 5: If the chair is still not receiving power, replace the 
backrest.

Remote

If the remote control beeps repeatedly even when you are 
not pushing any buttons:

The HT-Connect board is not working properly. Replace the HT-Connect 
board. If this problem is occurring and you have already replaced the 
HT-Connect board, replace the HT-Connect board again, along with the 
remote. If this does not resolve the problem, replace the backrest.

If one or more remote control LEDs do not light when you 
push the corresponding button, but the function the button 
controls works properly:

The remote control is not working properly. Verify that the remote control 
cable connection to the backrest cover is secure. If that does not solve 
the problem, replace the remote.

If the remote control LED lights but the function it controls 
is not working properly:

The problem is most likely in the function controlled by the remote, not 
in the remote itself. See the section pertaining to the function that is not 
working for further diagnosis.

Foot and Calf Massager 

The foot and calf massager collides with the seat when I try 
to retract it, and then it shuts down:

NOTE

Do not attempt to retract the foot and calf massager while 
sitting on the front edge of the seat cushion—this may cause 
the foot and calf massager to collide with the seat.

Summary of Contents for acuTouch 9500

Page 1: ...troubleshooting guide acuTouch 9500 9500x...

Page 2: ...2013 Human Touch LLC All rights reserved October 26 2013 Please forward any questions or comments regarding this Troubleshooting Guide to documentation humantouch com...

Page 3: ...the chair to Off wait approximately five seconds then turn it back On 2 Wait 30 seconds while a system check is performed observing whether the backrest massage mechanism and the foot and calf massage...

Page 4: ...inflating or deflating replace the chair base My Seat massage is not working The seat massage does not work at all replace the chair base The seat massages only on one side replace the chair base The...

Page 5: ...the wall outlet 1 Plug a different device into the AC outlet into which the chair is plugged 2 If the device does not work is not receiving power the AC outlet is most likely not working Plug the chai...

Page 6: ...e or more remote control LEDs do not light when you push the corresponding button but the function the button controls works properly The remote control is not working properly Verify that the remote...

Page 7: ...tion Adjusting the Rotation Release Handle 5 If the foot and calf massager still collides with the seat when retracting remove the seat cushion and then reinstall it making sure that the cushion is po...

Page 8: ...up for the foot and calf massage and circulation functions to work 1 Using the remote control Legs Down button attempt to fully retract the foot and calf massager until it beeps twice and then fully d...

Page 9: ...roke Replace the chair base Back Massage Choose from the following Heat IMPORTANT The heater heats slowly taking at least five minutes to warm up 1 Press the Heat button on the remote control 2 Watch...

Page 10: ...with the actuator 6 If this does not solve the problem there is likely a defective cable harness in the chair base Replace the chair base The backrest will not recline all the way but will incline 1...

Page 11: ...will blow the fuse 2 Verify that the device being plugged into the convenience outlet works when plugged into a wall outlet 3 Turn the power switch to OFF and unplug the chair from the wall outlet 4...

Page 12: ...Human Touch LLC 3030 Walnut Ave Long Beach CA 90807 humantouch com...