020-9905 User Manual Q3 (Advanced 3 year old child) Rev G Page 13 of 82
© 2016 Humanetics Innovative Solutions
3. Instrumentation
3.1 General
The dummy accepts both accelerometers and load cells as standard instrumentation.
Angular velocity sensors (DTS-ARS and Applied Technologies Associates type ARS-01 or
ARS-06 (flanged version)) can be fitted to the head; this requires an alternative head
accelerometer mount. The dummy can be equipped with uni-axial accelerometers for all
locations. Tri-axial accelerometers can be used on the pelvis and thorax location. The
standard dummy will be delivered including mounting blocks for uni-axial
accelerometers.
The load cells or its structural replacements are a part of the dummy structure; the
structural replacements have to be used in absence of the actual transducer. A 6-channel
load cell (Humanetics model IF-217 or IF-218) can be placed in the upper neck, lower
neck and lumbar spine location.
3.2 Transducers
The Q3 dummy can be fitted to measure any or all of the following parameters (see also
notes below):
Head
Standard - 3 uni-axial accelerometers in head (Ax, Ay, Az)
Optional - 3 angular velocity sensors:
Applied Technologies Associates type ARS-01 or ARS-06 (flanged version)
or DTS-ARS.
Neck
Standard - Upper neck 6 channel load cell, 3 forces, 3 moments (Fx, Fy, Fz, Mx, My,
Mz). Humanetics Model IF-217 (350 Ohm) or IF-218 (120 Ohm).
- Lower neck 6 channel load cell, 3 forces, 3 moments (Fx, Fy, Fz, Mx, My,
Mz). Humanetics Model IF-217 (350 Ohm) or IF-218 (120 Ohm).
Thorax
Standard - 3 uni-axial accelerometers (or tri-axial accelerometer) in upper spine (Ax,
Ay, Az).
- 1 IR-TRACC sensor to measure chest deformation, frontal or lateral (Dx or
Dy). Humanetics model IF-362.
Optional - Additional accelerometers may be installed with double sided tape on the
thoracic spine (Ax, Ay) (see notes below).