7.2 Equipment
Head Drop Table
For the free-fall head drop test a support and release mechanism is necessary as well as
steel plate with a thickness of at least 50 mm which will act as an impact surface. This
plate should be similar to the plate described in CFR 49, Part 572 Hybrid III head drop
test, and should have equivalent roughness and size.
Neck and Lumbar Spine Certification Equipment
A pendulum which meets the requirements of CFR 49 part 572.33(c) is needed to perform
the certifications of the neck and lumbar spine, see sections 8.6 and 8.7. The spine or
neck is mounted upside down on the pendulum arm using an interface plate which
replaces the standard part 572 pendulum mounting plate. To load the part, a head form
is used, which is shown in Figure 22, 23 and 24. Part numbers are listed in table 17.
Figure 22.
Q-series neck and lumbar spine head form test set-up for frontal test