11. Switching the detector on- and off
If the smoke detector is inserted into the base, it starts operation auto-
matically and carries out a self-test.
If it is removed from the base, the smoke detector turns off after 5
minutes. If the detector is removed from the base during an alarm, the
alarm is muted.
12. Maintenance and care
In order to ensure the operational reliability of the detector, according
to DIN EN 14676 servicing has to be carried out at least once a year.
Proceed as follows:
Remove dust from the detector with a soft cloth if necessary
Remove dirt with a damp cloth if necessary. Do not use cleaning
agents.
Visual check:
Are the smoke apertures clear?
Is the smoke detector damaged?
Is there free open space of > 0,5 m around the detector?
Has the purpose/usetype of the room been changed?
1.
2.
3.