background image

 

Humidex BSF 

 

Wiring Diagram for Model Numbers:

BSF-180

Revision 1.0

Mechatronics 

Fan

#UF15PC12

3uF

Cap

Yellow

6uF

Cap

Black

Green

White

Fan

Black

Black

Green

(Ground)

3 Position Switch

MEDIUM

HIGH

4uF

Cap

 

Summary of Contents for BSF-150

Page 1: ...015 Humidex BSF Rev 3 1En Installation Owner s Manual English This Manual Covers the Following Models BSF 150 BSF 180 Manufactured by ClairiTech Innovations Inc 1095 Ohio Rd Boudreau Ouest NB Canada E4P 6N4 ...

Page 2: ...OMER ASSISTANCE 2 CONSUMER LIMITED WARRANTY 3 Pre Installation 4 INCLUDED COMPONENTS 4 TOOLS REQUIRED FOR INSTALLATION 4 Installation 5 KEY INSTALLATION FACTS 5 INSTALLATION DIAGRAM 5 Unit Operations 6 THE CONTROLS 6 Specifications 7 TECHNICAL DATA 7 DIMENSIONS 7 SCHEMATIC OF WIRING 8 ...

Page 3: ...es please record below the model and serial number located on the side of the unit Product Name Model Date of Manufacturing Date of Purchase Serial Dealer Name If Any Please Note the above information before contacting us IMPORTANT To properly validate your warranty you must fill out and return the warranty card as soon as possible If your unit is not registered a proof of purchase will be necessa...

Page 4: ...duration of any warranties beyond the time period described herein on behalf of ClairiTech Innovations Inc The warranties described herein shall be the sole and exclusive warranties granted by ClairiTech and shall be the sole and exclusive remedy available to the purchaser Correction of defects in the manner and for the period of time described herein shall constitute complete fulfillment of all l...

Page 5: ...S 1 888 533 1348 Can 1 800 416 9111 1x Owner s Manual 6x 8 x 9 16 Screws 1x Warranty Card 4x 8 x 2 Screws 1x Universal Boot 4x 8 x 1 Truss Screws 4Ft 6 Insulated Flex 2x 4 x 12 Toe Space Grill 2x Cable Ties 4x Plastic Anchors Additional grilles for replenishment air and interior rooms not included Tools Required for Installation Electric reciprocal or hole saw 6 Drill with a concrete bit Phillips ...

Page 6: ...s in your area require a backdraft damper to be installed it must be placed on the exhaust side of the BSF to limit the impact on the total airflow thru the unit Not Included 5 This unit is typically sold with an Exhaust system Humidex or Wave If this is the case then this BSF system is made to replace your Replenishment vent required by the Exhaust system Installation Diagram Humidex or Wave Unit...

Page 7: ...your Humidex or Wave Exhaust system E g if your Humidex or Wave Exhaust system is set to Medium then the BSF system should also be set to medium Note In Cold basements the BSF fan speed should start at low and be incremented slowly This will prevent any temperature shock that will also stop condensation from forming and humidity from rising E g Basement is 60 F start the BSF system on Low and slow...

Page 8: ... Data Model Amps A Watts W Airflow CFM Low Med High BSF 150 0 26 31 55 95 150 BSF 180 0 26 31 55 120 180 All Units require a 115 VAC electrical outlet Dimensions Model Height In Width In Depth In BSF 150 11 10 25 7 25 BSF 180 11 10 25 7 25 ...

Page 9: ...8 Schematic of Wiring Wiring Diagram for Model Numbers BSF 150 Revision 1 0 Mechatronics Fan UF15PC12 2 7uF Cap Yellow 4uF Cap Black Green White Fan Black Black Green Ground 3 Position Switch MEDIUM HIGH 3 75uF Cap ...

Page 10: ...Humidex BSF 9 Wiring Diagram for Model Numbers BSF 180 Revision 1 0 Mechatronics Fan UF15PC12 3uF Cap Yellow 6uF Cap Black Green White Fan Black Black Green Ground 3 Position Switch MEDIUM HIGH 4uF Cap ...

Reviews: