ElectroVap RTH
Valve Maintenance
Maintenance
Drain valve maintenance
Drain steam tank out and switch unit off.
Remove screw 1 then swing coil holder 2 to the
left.
Remove coil 3 from the actuator assembly 4
(don’t miss the small parts).
Dismount assembly 5, clean valve 6 and rinse
body 7.
Reassemble all the parts .
Change parts if needed.
Swing coil holder 2 back and tighten screw 1.
1
Inlet valve maintenance
Turn the water supply off and switch humidifier off.
Remove water inlet hose.
Take out filter 2 with a pair of pliers and flush it with
clear water.
Pull coil 3 out with the help of a small screwdriver.
Flush with clear water the internal part of valve body 4.
Change parts if needed.
Reassemble.
27
2
4
3
2
1
3
4
5
6
7