36
Upper Range
(Advanced: Sonar, Split Sonar, Big Digits
and Circular Flasher views only)
Upper Range
sets the shallowest depth range that will be displayed on the Sonar, Split
Sonar, Big Digits and Circular Flasher Views. The Upper Range menu choice is available
when User Mode is set to Advanced (see
Setup Menu Tab: User Mode
) and can only be
accessed from the Sonar, Split Sonar, Big Digits and Circular Flasher Views. Upper Range
is often used with Lower Range.
NOTE:
A minimum distance of 10 feet will be maintained between the Upper and Lower
Range regardless of the manual settings entered.
To adjust the Upper Range:
1. Make sure you are in Advanced Mode, then highlight Upper Range on the
Sonar X-Press
TM
menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to increase or decrease the
Upper Range setting. (0 to 990 feet or 0 to 327 meters
[International Models
only]
, Default = 0)
For example, if you are only interested in the area between 20 and 50
feet deep, you should set the Upper Depth Range to 20 and the Lower
Depth Range to 50. The Sonar View will then show the 30 foot area
between 20 and 50, and will not show the surface or the bottom
(assuming the bottom is deeper than 50 feet), and will show greater
detail for that area between 20 and 50 feet.
35
Sensitivity
Sensitivity
controls how much detail is shown on the
display and will adjust the sensitivity of all sonar frequencies. Increasing the sensitivity
shows more sonar returns from small baitfish and suspended debris in the water;
however, the display may become too cluttered. When operating in very clear water or
greater depths, increased sensitivity shows weaker returns that may be of interest.
Decreasing the sensitivity eliminates the clutter from the display that is sometimes
present in murky or muddy water. If Sensitivity is adjusted too low, the display may not
show many sonar returns that could be fish.
NOTE:
The Sensitivity setting is a global setting and will adjust the sensitivity of all sonar
frequencies, as compared to specific sensitivity adjustments (such as 83 kHz Sensitivity) that
allow you to adjust the level of sensitivity for one specific beam at a time.
To adjust the Sensitivity:
1. Highlight Sensitivity on the Sonar X-Press
TM
menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to increase or decrease the
Sensitivity setting. (Low = 1, High = 20, Default = 10)
Sensitivity at Low
Sensitivity at Medium
Sensitivity at High
531448-1_A - 363_Man_Eng.qxd 11/9/2005 6:07 PM Page 42