background image

1000/1005 SPECIFICATIONS

Operating Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 kHz

Power Output  . . . . . . . . . . . . . . . . . . . . . . .4000 Watts (Peak to Peak)

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 Watts (RMS)

Area of Coverage   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24° at -3 dB 

Power Requirement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 - 20 VDC

Display  . . . . . . . . . . . . . . . . . . . . . . . . . . 8 level FSTN Grayscale LCD

LCD Matrix  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 H x 160 V

Viewing Area  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

³⁄₅

" H x 3

³⁄₅

" V

Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .In-dash or Tilt

Unit Size   . . . . . . . . . . . . . . . . . . . . . . . 4

¹³⁄₁₆

" V x 6

³⁄₁₆

" W x 2

³⁄₄

" D

Transducer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single beam

Transducer Cable Length  . . . . . . . . . . . . . . . . . . . . . . . 20' (6 metres)

1000 DEEP/1005 DEEP SPECIFICATIONS

Operating Frequencies . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/200 kHz

Power Output  . . . . . . . . . . . . . . . . . . . . . . .4000 Watts (Peak to Peak)

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 Watts (RMS)

Area of Coverage   . . . . . . . . . . . . . . . . . . . . . .20° and 74° at -10 dB 

Power Requirement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 - 20 VDC

Display  . . . . . . . . . . . . . . . . . . . . . . . . . . 8 level FSTN Grayscale LCD

LCD Matrix  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 H x 160 V

Viewing Area  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

³⁄₅

" H x 3

³⁄₅

" V

Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .In-dash or Tilt

Unit Size   . . . . . . . . . . . . . . . . . . . . . . . 4

¹³⁄₁₆

" V x 6

³⁄₁₆

" W x 2

³⁄₄

" D

Transducer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dual beam

Transducer Cable Length  . . . . . . . . . . . . . . . . . . . . . . . 20' (6 metres)

1005/1005 DEEP SPECIFICATIONS
(INTERNATIONAL MODELS)

Languages Supported Include: English, Dansk, Deutsch, Español,
Finnish/Svomi, Français, Italiano, Nederlands, Norsk, Portuquês, Svenska,
Magvar and Polski.

Additional units of measurement: Metres, Fathoms and °C.

SPECIFICATIONS

16

Summary of Contents for Legend 1000

Page 1: ...Operations Manual Operational instructions for Humminbird Legend 1000 Series including the Legend 1000 1005 1000 Deep and 1005 Deep...

Page 2: ...nbird com WARNING This device should not be used as a navigational aid to prevent collision grounding boat damage or personal injury When the boat is moving water depth may change too quickly to allow...

Page 3: ...oom Mode 8 Manual Mode 8 Chart Speed 9 Sonar View 9 Light 9 Contrast 9 RTS Window 9 Surface Clutter 10 White Line 10 Filter 10 Depth Alarm 10 Temp Alarm 11 Fish Alarm 11 Fish Sensitivity 11 Fish ID 11...

Page 4: ...chirp sounds as the unit turns on If the unit detects that the transducer is connected and is in water the LEGEND 1000 SERIES begins to show sonar information on the display If the transducer is not...

Page 5: ...L knob again If no adjustments are made after a few seconds the CONTROL PANEL list is removed automatically Range Knob The RANGE knob adjusts the depth ranges used on the display The RANGE knob has sl...

Page 6: ...ft bottom shows more gray below Structure appears above the bottom as a cluster of lines with varying lengths and gray shades Fish appear as smaller groupings of sonar returns between the bottom and s...

Page 7: ...e speed and direction over the location where the structure was originally located Thermoclines The LEGEND 1000 SERIES is also capable of showing layers of water having different temperatures These te...

Page 8: ...adjusted by using the RANGE knob The active CONTROL PANEL consists of three parts the CONTROL PANEL NAME SETTING INDICATOR and SETTING READOUT The CONTROL PANEL NAME indicates the feature the SETTING...

Page 9: ...depth range to keep the bottom on screen The LEGEND 1000 SERIES uses a depth range to keep the bottom contour close to the bottom of the display To return the depth range to normal viewing turn the un...

Page 10: ...membered until the LEGEND 1000 SERIES is powered off when the unit defaults to factory settings Manual Mode MANUAL mode turns off automatic bottom tracking leaving control of the depth range to the us...

Page 11: ...rightness so the display will be visible at night The backlight will then begin to decrease in intensity automatically until it is off in order to save energy Selecting the CONTROL PANEL LIGHT choice...

Page 12: ...m composition and structure is reduced Selecting a smaller numeric setting narrows the band and shows greater variation in bottom composition Selecting OFF turns the WHITE LINE feature off The WHITE L...

Page 13: ...settings OFF plus the three different fish symbols shown onscreen see FISH ID The 1000 Deep 1005 Deep can be set to alarm only large fish displayed as a large fish symbol only large and medium fish di...

Page 14: ...e CONTROL PANELS and for messages See the LEGEND 1005 1005 DEEP Specifications for included languages LANGUAGE setting is retained in memory after the LEGEND 1005 1005 DEEP is turned off The factory s...

Page 15: ...nit Next inspect the transducer cable from end to end for breaks kinks or cuts in the outer casing of the cable and repair after disconnecting the cable from both the unit and the transducer Also make...

Page 16: ...15 380mm from the prop 10 The screen does not display a full fish arch Check the running angle of the transducer If the running angle is too great a full fish arch may not appear Reduce the running a...

Page 17: ...pair Authorization Number for your unit Please have your product model name and serial number available before calling the factory If you contact the factory by e mail please include your product mode...

Page 18: ...g Frequencies 50 200 kHz Power Output 4000 Watts Peak to Peak 500 Watts RMS Area of Coverage 20 and 74 at 10 dB Power Requirement 10 20 VDC Display 8 level FSTN Grayscale LCD LCD Matrix 160 H x 160 V...