HTP-T800 User Manual
-57-
z
1500V isolation (input to output)
.
PoE must be protected from over-voltages exceeding the 80V maximum rated surge input
voltage
1.
Recommended Operating Conditions
Parameter Min
Typ
Max
Units
1
DC Supply Voltage
36
48
57
V
2
DC Voltage Lockout
30
36
V
3
Operating Temperature
-20
25
70
Ta/°C
2.
DC Electrical Characteristics
Parameter Min
Typ
Max
Units
1
Nominal Output Voltage
11.5
12.0
12.5
V
2
Output Current
(V
IN
= 48V)
1.0
A
3
Line Regulation
0.1
%
4
Load Regulation
1
%
5
Output Ripple and Noise
100
mVp-p
6
Minimum Load
100
mA
7
Short-Circuit Duration
∞
sec
8
Efficiency @ 80% Load
87
%
9
Isolation Voltage (I/O)
1500
V
dc
10
Temperature Coefficient
0.02
%
Note 1: Typical figures are at 25°C with a nominal 48V supply and are for design aid only. Not Guaranteed
2: The output ripple and noise can be reduced with an external filter, see application note.
3: Continuous short circuit duration is applicable at 25'C ambient temperature in free air. At higher temperatures
or with restricted airflow (e.g. in a sealed enclosure) the duration will need to be limited to avoid overheating.
Summary of Contents for HTP-T800
Page 1: ...HTP T800 H 264 VIDEO SERVER User Manual Ver 1 0...
Page 18: ...HTP T800 User Manual 17 Http port 80...
Page 22: ...HTP T800 User Manual 21 2 2 Video Configuration...
Page 27: ...HTP T800 User Manual 26 2 4 Network Configuration...
Page 30: ...HTP T800 User Manual 29 2 5 Serial Port Configuration...
Page 32: ...HTP T800 User Manual 31...
Page 33: ...HTP T800 User Manual 32 2 6 Event Configuration...